OSHA SearchOSHA records by employer

2L Construction LLC: OSHA inspections and violations

Flower Mound, Texas · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
5citation items
$13,575current penalties
Jun 9, 2021last inspection

OSHA inspectors have visited 2L Construction LLC in Texas one time.

It opened on Jun 9, 2021 as a planned inspection, in Flower Mound.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $22,625; today they stand at $13,575, 40% less.

The rule cited most here is 1926.651 (excavations), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. 2L Construction LLC averages $13,575 across 1 cited inspection.

2L Construction LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites 2L Construction LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345356893 OPENED JUN 9, 2021Closed

Planned · Partial · Safety · 25 employees at the site · Closed Jul 5, 2022

Morriss Rd And Valley Ridge Blvd, Flower Mound, TX 75028 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$3,901$2,341Jul 15, 2021Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$5,461$3,277Jul 15, 2021Final
Citation 1, item 3
29 CFR 1926.651(k)(1) · Excavations
Serious$3,901$2,341Jul 15, 2021Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$5,461$3,277Jul 15, 2021Final
Citation 1, item 5
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$3,901$2,341Jul 15, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other poured concrete foundation and structure contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.