OSHA SearchOSHA records by employer

4-S Manufacturing, LLC: OSHA inspections and violations

Hempstead, Texas · Other Concrete Product Manufacturing · NAICS 327390

1inspections
7citation items
$30,527current penalties
May 15, 2019last inspection

OSHA has inspected 4-S Manufacturing, LLC once in Texas.

The inspection began on May 15, 2019 after a complaint, in Hempstead.

That inspection ended with 7 citation items: 6 serious and 1 other-than-serious.

Penalties were first proposed at $51,146 and now stand at $30,527, 40% lower after settlements or reviews.

Overhead and gantry cranes comes up most often in these citations: 2 items under 1910.179.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and 4-S Manufacturing, LLC averages $30,527 (1 cited inspection).

It reported 2 severe injuries to OSHA since 2015.

4-S Manufacturing, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch 4-S Manufacturing, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344017082 OPENED MAY 15, 2019Closed

Complaint · Partial · Health · 242 employees at the site · Closed May 12, 2022

44855 Old Houston Hwy, Hempstead, TX 77445 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$11,934$7,160Sep 9, 2019Final
Citation 1, item 2
29 CFR 1910.179(d)(4)(iii) · Overhead and gantry cranes
Serious$8,525$5,115Sep 9, 2019Final
Citation 1, item 3
29 CFR 1910.179(l)(3)(i) · Overhead and gantry cranes
Serious$11,934$7,160Sep 9, 2019Final
Citation 1, item 4
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$6,819$4,091Sep 9, 2019Final
Citation 2, item 1
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Sep 9, 2019Final
Citation 3, item 1a
29 CFR 1910.1053(c) · Silica dust in general industry
Serious$11,934$7,000Oct 24, 2019Final
Citation 3, item 1b
29 CFR 1910.1053(f)(1) · Silica dust in general industry
Serious$0$0Oct 24, 2019Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Jan 19, 2024, Hempstead: Hospitalization · surface, flesh wounds and soft tissue injuries · trunk and other lower extremities

An employee was on a ladder patching a leak in the ceiling when they slipped and fell 8 to 10 feet to the floor. The employee suffered a left leg strain and contusions to the body and was hospitalized.

Apr 24, 2019, Hempstead: Hospitalization · fractures · multiple body parts, n.e.c.

An employee was using a crane to load a concrete I-beam on a flatbed when the crane's chain broke, releasing the I-beam. The I-beam struck the employee, knocking him to the flatbed and then the ground. He suffered fractures to the back, shoulder, and knees.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(c)

(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of respirable crystalline silica in excess of 50 µg/m 3, calculated as an 8-hour TWA.

29 CFR 1910.1053(f)(1)

(f) Methods of compliance—(1) Engineering and work practice controls. The employer shall use engineering and work practice controls to reduce and maintain employee exposure to respirable crystalline silica to or below the PEL, unless the employer can demonstrate that such controls are not feasible. Wherever such feasible engineering and work practice controls are not sufficient to reduce employee exposure to or below the PEL, the employer shall nonetheless use them to reduce employee exposure to the lowest feasible level and shall supplement them with the use of respiratory protection that complies with the requirements of paragraph (g) of this section.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(k)(6)

(6) The basic advisory information on respirators, as presented in appendix D of this section, shall be provided by the employer in any written or oral format, to employees who wear respirators when such use is not required by this section or by the employer.

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.252 · Welding fire safety

Other other concrete product manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.