OSHA SearchOSHA records by employer

42 North Builders LLC: OSHA inspections and violations

Providence, Rhode Island · Residential Remodelers · NAICS 236118

1inspections
4citation items
$2,216current penalties
Nov 19, 2018last inspection

42 North Builders LLC has one OSHA inspection on record in Rhode Island.

OSHA opened it on Nov 19, 2018 as a planned inspection, in Providence.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $3,880 in penalties. After settlements and reviews the total is $2,216, down 43%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. 42 North Builders LLC averages $2,216 over 1 cited inspection in that time.

42 North Builders LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

81employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch 42 North Builders LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343609269 OPENED NOV 19, 2018Closed

Planned · Partial · Safety · 10 employees at the site · Closed Jun 12, 2019

325 Wayland Ave., Providence, RI 02905 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$3,880$2,216Jan 3, 2019Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Jan 3, 2019Final
Citation 1, item 1c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Jan 3, 2019Final
Citation 1, item 1d
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Jan 3, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

Other residential remodelers employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.