OSHA SearchOSHA records by employer

4D Inspiration Company LLC: OSHA inspections and violations

Orlando, Florida · Framing Contractors · NAICS 238130

1inspections
4citation items
$8,472current penalties
Jun 5, 2023last inspection

4D Inspiration Company LLC has one OSHA inspection on record in Florida.

OSHA opened it on Jun 5, 2023, in Orlando.

From that inspection OSHA issued 4 citation items: 3 serious and 1 other-than-serious.

OSHA proposed $15,404 in penalties. After settlements and reviews the total is $8,472, down 45%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. 4D Inspiration Company LLC averages $8,472 over 1 cited inspection in that time.

4D Inspiration Company LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

41 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch 4D Inspiration Company LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346754534 OPENED JUN 5, 2023Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Nov 21, 2025

2011 Peel Ave Lot 4, Orlando, FL 32806 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$4,018$2,210Sep 21, 2023Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,688$2,578Sep 21, 2023Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Other-than-serious$3,349$1,842Sep 21, 2023Final
Citation 1, item 4
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$3,349$1,842Sep 21, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(12)

(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.