OSHA SearchOSHA records by employer

4M Construction Inc.: OSHA inspections and violations

Brooklyn, New York · Masonry Contractors · NAICS 238140

2inspections
9citation items
$18,848current penalties
Jan 16, 2019last inspection

4M Construction Inc. has 2 OSHA inspections on record in New York, the first in 2018.

OSHA's last visit started on Jan 16, 2019 to follow up on an earlier case, in Brooklyn.

Across those inspections OSHA issued 9 citation items: 9 serious.

OSHA proposed $18,848 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. 4M Construction Inc. averages $18,848 over 1 cited inspection in that time.

4M Construction Inc.: OSHA citation items per year, 2018 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

359employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch 4M Construction Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343718961 OPENED JAN 16, 2019Closed

Follow-up · No inspection · Safety · Closed Jan 23, 2019

231 Ainslie Street, Brooklyn, NY 11211 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343079141 OPENED APR 9, 2018Closed

Referral · Partial · Safety · 5 employees at the site · Closed Jan 19, 2023

231 Ainslie Street, Brooklyn, NY 11211 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,880$3,880Jun 22, 2018Final
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Jun 22, 2018Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$2,772$2,772Jun 22, 2018Final
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Serious$2,772$2,772Jun 22, 2018Final
Citation 1, item 4a
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$3,880$3,880Jun 22, 2018Final
Citation 1, item 4b
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$0$0Jun 22, 2018Final
Citation 1, item 5a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,772$2,772Jun 22, 2018Final
Citation 1, item 5b
29 CFR 1926.1053(b)(7) · Ladders in construction
Serious$0$0Jun 22, 2018Final
Citation 1, item 6
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$2,772$2,772Jun 22, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.