OSHA SearchOSHA records by employer

5G Masonry dba Rosales Masonry LLC: OSHA inspections and violations

Burnsville, Minnesota · Masonry Contractors · NAICS 238140

1inspections
2citation items
$14,000current penalties
Aug 20, 2019last inspection

OSHA inspectors have visited 5G Masonry dba Rosales Masonry LLC in Minnesota one time.

It opened on Aug 20, 2019 as a planned inspection, in Burnsville.

In all, OSHA issued 2 citation items: 2 serious.

The penalties, $14,000 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. 5G Masonry dba Rosales Masonry LLC averages $14,000 across 1 cited inspection.

5G Masonry dba Rosales Masonry LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

374employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch 5G Masonry dba Rosales Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344249743 OPENED AUG 20, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Feb 25, 2020

7 Travelers Trail W, Burnsville, MN 55337 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$7,000$7,000Jan 29, 2020Final
Citation 1, item 2
29 CFR 1926.454(a) · Scaffold training
Serious$7,000$7,000Jan 29, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.454(a)

(a) The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:

Other masonry contractors employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.