OSHA SearchOSHA records by employer

6-B Construction, LLC.: OSHA inspections and violations

Gulfport, Mississippi · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
4citation items
$19,356current penalties
May 1, 2024last inspection

OSHA inspectors have visited 6-B Construction, LLC. in Mississippi one time.

It opened on May 1, 2024 as a planned inspection, in Gulfport.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $19,356 in total, stand where OSHA first set them.

The rule cited most here is 1926.651 (excavations), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. 6-B Construction, LLC. averages $19,356 across 1 cited inspection.

6-B Construction, LLC.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites 6-B Construction, LLC. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347453144 OPENED MAY 1, 2024Closed

Planned · Partial · Safety · 7 employees at the site · Closed Apr 2, 2025

13830 S. Swan Rd., Gulfport, MS 39503 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$4,839$4,839Jun 5, 2024Final
Citation 1, item 2
29 CFR 1926.651(h)(1) · Excavations
Serious$4,839$4,839Jun 5, 2024Final
Citation 1, item 3
29 CFR 1926.651(k)(2) · Excavations
Serious$4,839$4,839Jun 5, 2024Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,839$4,839Jun 5, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(h)(1)

(h) Protection from hazards associated with water accumulation. (1) Employees shall not work in excavations in which there is accumulated water, or in excavations in which water is accumulating, unless adequate precautions have been taken to protect employees against the hazards posed by water accumulation. The precautions necessary to protect employees adequately vary with each situation, but could include special support or shield systems to protect from cave-ins, water removal to control the level of accumulating water, or use of a safety harness and lifeline.

29 CFR 1926.651(k)(2)

(2) Where the competent person finds evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees shall be removed from the hazardous area until the necessary precautions have been taken to ensure their safety.

29 CFR 1926.652 · Trench protection