712 Montgomery ST.: OSHA inspections and violations

Brooklyn, New York · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
5citation items
$7,500current penalties
Nov 28, 2017last inspection

OSHA inspectors have visited 712 Montgomery ST. in New York one time.

It opened on Nov 28, 2017 as a planned inspection, in Brooklyn.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $18,478; today they stand at $7,500, 59% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. 712 Montgomery ST. averages $7,500 across 1 cited inspection.

712 Montgomery ST.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch 712 Montgomery ST. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342801743 OPENED NOV 28, 2017Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jul 29, 2020

716 Montgomery St., Brooklyn, NY 11213 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3a
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$5,174$2,900May 22, 2018Final
Citation 1, item 3b
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$0$0May 22, 2018Final
Citation 1, item 4
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$4,434$2,525May 22, 2018Final
Citation 1, item 5a
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$3,696$2,075May 22, 2018Final
Citation 1, item 5b
29 CFR 1926.304(h)(1) · Woodworking tools
Serious$5,174$0May 22, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(h)(1)

(h) Hand-fed crosscut table saws. (1) Each circular crosscut table saw shall be guarded by a hood which shall meet all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

Other new single-family housing construction (except for-sale builders) employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.