A-1 Electric Ltd has 23 OSHA inspections on record in Texas, the first in 1978.
OSHA's last visit started on Jan 22, 2017 after a fatality or catastrophe, in Amarillo.
Across those inspections OSHA issued 29 citation items: 8 serious, 4 repeat and 17 other-than-serious.
OSHA proposed $16,747 in penalties. After settlements and reviews the total is $14,447, down 14%.
Most often, OSHA cited 1926.405, job-site wiring (8 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. A-1 Electric Ltd averages $12,675 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
Inspection 342046901 OPENED JAN 22, 2017Closed
Fatality or catastrophe · Partial · Safety · 35 employees at the site · Closed Jan 2, 2018
790 S. Buchannan, Amarillo, TX 79106 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Jan 21, 2017 (fatal): Two employees are injured in electrical arc flash, one later
At about 1:00 p.m. on January 21, 2017, Employees #1 and #2 were performing electrical work inside an electrical room at a facility. They experienced an electrical arc flash that resulted in an explosion and fire. The employees were taken to Northwest hospital in Amarillo in critical condition for treatment and transferred to University Medical Center (UMC) burn center in Lubbock. On January 22, 2017, Employee #1 died.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 3 |
Serious | $12,675 | $12,675 | Jul 19, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.