OSHA SearchOSHA records by employer

A-1 Electrical Contractors, Inc.: OSHA inspections and violations

Metairie, Louisiana · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

7inspections
6citation items
$9,256current penalties
Feb 27, 2018last inspection

Since 2002, OSHA inspectors have visited A-1 Electrical Contractors, Inc. in Louisiana 7 times.

The most recent inspection opened on Feb 27, 2018, in Covington.

In all, OSHA issued 6 citation items: 6 serious.

The proposed penalties came to $15,427; today they stand at $9,256, 40% less.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. A-1 Electrical Contractors, Inc. averages $5,856 across 1 cited inspection.

A-1 Electrical Contractors, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

A-1 Electrical Contractors, Inc.: OSHA citation items per year, 2002 to 2018
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch A-1 Electrical Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342978129 OPENED FEB 27, 2018Closed

Unprogrammed other · Partial · Safety · 15 employees at the site · Closed Feb 28, 2018

8080 Westshore Drive, Covington, LA 70433 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341996932 OPENED DEC 28, 2016Closed

Referral · Partial · Safety · 71 employees at the site · Closed Mar 24, 2017

2001 Millerville Road, Baton Rouge, LA 70816 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$9,760$5,856Feb 28, 2017Final

Inspection 334632585 OPENED MAY 24, 2012Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Jul 13, 2012

3338 St Charles Ave, New Orleans, LA 70115 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$2,975$1,785Jul 2, 2012Final

Inspection 311242960 OPENED AUG 7, 2007Closed

Planned · Complete · Safety · 2 employees at the site · Closed Sep 6, 2007

3645 I-10 Service Road, Metairie, LA 70002 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$446$268Aug 17, 2007Closed
Citation 1, item 2
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$446$268Aug 17, 2007Closed

Inspection 310830278 OPENED MAY 2, 2007Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed May 2, 2007

1901 Manhattan Blvd. - Maint. Bldg., Harvey, LA 70056 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310451232 OPENED OCT 12, 2006Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 25, 2007

2900 Ridgelake Dr., Metairie, LA 70003 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$750$450Jan 9, 2007Closed

Inspection 304478373 OPENED JUL 17, 2002Closed

Planned · Partial · Safety · 2 employees at the site · Closed Oct 9, 2002

103 Bercegeay, Broussard, LA 70518 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,050$630Sep 13, 2002Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Harvey site logged 1 recordable injury or illness among about 170 workers: 0.6 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
A-1 Electrical Contractors, Inc.
Harvey · 2024
170 100.61.8

Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Dec 26, 2016, Baton Rouge: Hospitalization · herniated discs · neck, except internal location of diseases or disorders

While rewiring equipment on top of a larger cooler, an employee walked from one cooler to another and tripped, falling forward, then off the cooler and onto the ground approximately 8 feet below. The employee sustained facial lacerations and three herniated discs in the neck.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(1)

(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

Other electrical contractors and other wiring installation contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.