Inspection 347795205 OPENED OCT 1, 2024Closed
19 Jefferson Ave., Spring Valley, NY 10977 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected A-1 Iron Works Contracting Corp. 5 times in New York since 2018.
The latest one began on Oct 1, 2024 on a referral, in Spring Valley.
Those inspections ended with 8 citation items: 8 serious.
Penalties were first proposed at $44,238 and still stand at $44,238.
Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and A-1 Iron Works Contracting Corp. averages $22,119 (2 cited inspections).
New York · latest 90 days of OSHA records
362employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch A-1 Iron Works Contracting Corp. and get notified the morning OSHA posts a new citation for it.
Watch this company19 Jefferson Ave., Spring Valley, NY 10977 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1162 54th St., Brooklyn, NY 11219 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1162 54th Street, Brooklyn, NY 11219 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(4)(i) · Fall protection in construction |
Serious | $5,304 | $5,304 | Aug 13, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.1053(b)(4) · Ladders in construction |
Serious | $5,304 | $5,304 | Aug 13, 2019 | Final |
2813 Tilden Avenue, Brooklyn, NY 11226 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2813 Tilden Avenue, Brooklyn, NY 11226 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $5,174 | $5,174 | Sep 19, 2018 | Final |
| Citation 1, item 2 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Serious | $5,174 | $5,174 | Sep 19, 2018 | Final |
| Citation 1, item 3 29 CFR 1926.451(c)(3) · Scaffolds, general requirements |
Serious | $5,174 | $5,174 | Sep 19, 2018 | Final |
| Citation 1, item 4 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $5,174 | $5,174 | Sep 19, 2018 | Final |
| Citation 1, item 5 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $6,467 | $6,467 | Sep 19, 2018 | Final |
| Citation 1, item 6 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $6,467 | $6,467 | Sep 19, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.1053(b)(4)
(4) Ladders shall be used only for the purpose for which they were designed.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: