Inspection 348134792 OPENED MAR 26, 2025Closed
13056 Parham Lane, Stony Creek, VA 23882 · Sawmills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Stony Creek, Virginia · Sawmills · NAICS 321113
A a Gibbs Lumber Co has 4 OSHA inspections on record in Virginia, the first in 1995.
OSHA's last visit started on Mar 26, 2025 on a referral, in Stony Creek.
Across those inspections OSHA issued 31 citation items: 27 serious and 4 other-than-serious.
OSHA proposed $38,035 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.305, electrical wiring methods (8 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. A a Gibbs Lumber Co averages $38,035 over 1 cited inspection in that time.
A a Gibbs Lumber Co also files yearly injury logs with OSHA, summarized below.
Virginia · latest 90 days of OSHA records
250employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch A a Gibbs Lumber Co and get notified the morning OSHA posts a new citation for it.
Watch this company13056 Parham Lane, Stony Creek, VA 23882 · Sawmills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
13056 Parham Lane, Stony Creek, VA 23882 · Sawmills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 16VAC25-60-120 |
Serious | $3,175 | $3,175 | May 29, 2025 | Final |
| Citation 1, item 1b 29 CFR 16VAC25-60-120 |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 1c 29 CFR 16VAC25-60-120 |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 1d 29 CFR 16VAC25-60-120 |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 2a 29 CFR 1910.22(a)(1) · Walking-working surfaces |
Serious | $3,175 | $3,175 | May 29, 2025 | Final |
| Citation 1, item 2b 29 CFR 1910.23(c)(9) · Ladders in general industry |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 3a 29 CFR 1910.106(d)(6)(iii) · Flammable liquids |
Serious | $1,405 | $1,405 | May 29, 2025 | Final |
| Citation 1, item 3b 29 CFR 1910.106(d)(6)(iv) · Flammable liquids |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 4 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Serious | $2,685 | $2,685 | May 29, 2025 | Final |
| Citation 1, item 5 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $15,875 | $15,875 | May 29, 2025 | Final |
| Citation 1, item 6 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $2,685 | $2,685 | May 29, 2025 | Final |
| Citation 1, item 7a 29 CFR 1910.106(d)(7)(i) · Flammable liquids |
Serious | $3,175 | $3,175 | May 29, 2025 | Final |
| Citation 1, item 7b 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 7c 29 CFR 1910.157(e)(2) · Portable fire extinguishers |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 7d 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 8 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $2,685 | $2,685 | May 29, 2025 | Final |
| Citation 1, item 9a 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $3,175 | $3,175 | May 29, 2025 | Final |
| Citation 1, item 9b 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 9c 29 CFR 1910.305(b)(1)(i) · Electrical wiring methods |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 9d 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 9e 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 9f 29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 9g 29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 9h 29 CFR 1910.305(g)(1)(iv)(e) · Electrical wiring methods |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 9i 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 9j 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 1, item 9k 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | May 29, 2025 | Final |
| Citation 2, item 1a 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | May 29, 2025 | Final |
| Citation 2, item 1b 29 CFR 1910.1200(f)(6) · Hazard communication |
Other-than-serious | $0 | $0 | May 29, 2025 | Final |
| Citation 2, item 1c 29 CFR 1910.1200(g)(8) · Hazard communication |
Other-than-serious | $0 | $0 | May 29, 2025 | Final |
| Citation 2, item 1d 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | May 29, 2025 | Final |
300 Pocahontas Street, Petersburg, VA 23804 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
13056 Parham Lane, Stony Creek, VA 23882 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Stony Creek site logged 0 recordable injuries or illnesses among about 5 workers: 0.0 per 100 full-time workers, against a median of 4.2 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| A a Gibbs Lumber Co. Inc. Stony Creek · 2024 | 5 | 0 | 0 | 0.0 | 4.2 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(6)(iii)
(iii) Spill containment. The storage area shall be graded in a manner to divert possible spills away from buildings or other exposures or shall be surrounded by a curb at least 6 inches high. When curbs are used, provisions shall be made for draining of accumulations of ground or rain water or spills of flammable liquids. Drains shall terminate at a safe location and shall be accessible to operation under fire conditions.
29 CFR 1910.106(d)(6)(iv)
(iv) Security. The storage area shall be protected against tampering or trespassers where necessary and shall be kept free of weeds, debris and other combustible material not necessary to the storage.
29 CFR 1910.106(d)(7)(i)
(7) Fire control—(i) Extinguishers. Suitable fire control devices, such as small hose or portable fire extinguishers, shall be available at locations where flammable liquids are stored.
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.