A a Masonry: OSHA inspections and violations

Winston Salem, North Carolina · Masonry Contractors · NAICS 238140

3inspections
12citation items
$12,570current penalties
Oct 7, 2016last inspection

Since 1991, OSHA inspectors have visited A a Masonry in North Carolina 3 times.

The most recent inspection opened on Oct 7, 2016 as a planned inspection, in Winston Salem.

In all, OSHA issued 12 citation items: 8 serious, 3 repeat and 1 other-than-serious.

The penalties, $12,570 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 8 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. A a Masonry averages $4,200 across 1 cited inspection.

A a Masonry: OSHA citation items per year, 1991 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites A a Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341825503 OPENED OCT 7, 2016Closed

Planned · Partial · Safety · 6 employees at the site · Closed Dec 14, 2018

760 Patterson Avenue, Winston Salem, NC 27101 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,100$2,100Oct 14, 2016Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Oct 14, 2016Final
Citation 1, item 1c
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$0$0Oct 14, 2016Final
Citation 1, item 1d
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Oct 14, 2016Final
Citation 1, item 2a
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Serious$2,100$2,100Oct 14, 2016Final
Citation 1, item 2b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Oct 14, 2016Final

Inspection 18555490 OPENED OCT 7, 1991Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 10, 1995

1000 Yorkshire Road, Winston Salem, NC 27104 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Repeat$2,800$2,800Feb 14, 1992Closed
Citation 1, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Repeat$2,520$2,520Feb 14, 1992Closed
Citation 2, item 1
29 CFR 1926.50(d)(1) · Medical services and first aid
Repeat$350$350Feb 14, 1992Closed

Inspection 18555433 OPENED SEP 24, 1991Closed

Planned · Complete · Safety · 10 employees at the site · Closed Dec 20, 1991

420 S. Stratford Road, Winston Salem, NC 27103 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(d)(3) · Scaffolds, general requirements
Serious$1,380$1,380Nov 20, 1991Closed
Citation 1, item 2
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,320$1,320Nov 20, 1991Closed
Citation 2, item 1
29 CFR 1926.50(d)(1) · Medical services and first aid
Other-than-serious$0$0Nov 20, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(d)(10)

(10) Ropes shall be inspected for defects by a competent person prior to each workshift and after every occurrence which could affect a rope's integrity. Ropes shall be replaced if any of the following conditions exist:

29 CFR 1926.451(d)(3)

(3) The inboard ends of suspension scaffold outrigger beams shall be stabilized by bolts or other direct connections to the floor or roof deck, or they shall have their inboard ends stabilized by counterweights, except masons' multi-point adjustable suspension scaffold outrigger beams shall not be stabilized by counterweights.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.503 · Fall protection training in construction