OSHA SearchOSHA records by employer

A & D Fire Protection, Inc.: OSHA inspections and violations

Camp Pendleton, California · Commercial and Institutional Building Construction · NAICS 236220

11inspections
14citation items
$17,100current penalties
Jan 17, 2017last inspection

OSHA has inspected A & D Fire Protection, Inc. 11 times in California since 1991.

The latest one began on Jan 17, 2017 after an accident, in Los Angeles.

Those inspections ended with 14 citation items: 6 serious and 8 other-than-serious.

Penalties were first proposed at $28,120 and now stand at $17,100, 39% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 2 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and A & D Fire Protection, Inc. averages $14,100 (1 cited inspection).

A & D Fire Protection, Inc.: OSHA citation items per year, 1991 to 2017
Citation items per year, by inspection date.

California · latest 90 days of OSHA records

1,134employers cited

43 of them in the same industry

Get notified the morning OSHA posts each new citation in California: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in California

Checking a subcontractor, a client or your own company? Watch A & D Fire Protection, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342047214 OPENED JAN 17, 2017Closed

Accident · Partial · Safety · 35 employees at the site · Closed Dec 1, 2020

755 S. Spring St., Los Angeles, CA 90012 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 17, 2017: Employee falls from ladder and fractures leg

At 2:45 p.m. on January 17, 2017, an employee was located in a firewater storage tank and standing on an extension ladder to take a measurement. As he reached to measure the particular area of the tank, the ladder slipped. The employee fell 17 feet to the bottom of the tank, sustaining a fractured left leg. The employee was hospitalized and received treatment for his injury. The incident investigation reported that the ladder was not properly secured on the slippery surface of the tank, causing the ladder to slip.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1952(E)(2)(B)
Other-than-serious$410$75Dec 8, 2017Final
Citation 1, item 2
29 CFR 1960(B)(3)
Other-than-serious$410$75Dec 8, 2017Final
Citation 2, item 1
29 CFR 1952(E)(2)(C)
Serious$4,950$1,350Dec 8, 2017Final
Citation 3, item 1
29 CFR 1953(A)(9)
Other-than-serious$4,950$0Dec 8, 2017Final
Citation 4, item 1
29 CFR 1675(B)
Serious$14,400$12,600Dec 8, 2017Final

Inspection 307880161 OPENED JUL 27, 2004Closed

Planned · Partial · Safety · 68 employees at the site · Closed Jul 27, 2004

Building 508, Port Mugu, CA 93042 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109332288 OPENED DEC 9, 2003Closed

Planned · Complete · Safety · 4 employees at the site · Closed Dec 9, 2003

17012 Vandergrift, Camp Pendleton, CA 92055 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306378472 OPENED SEP 2, 2003Closed

Planned · Complete · Safety · 2 employees at the site · Closed Sep 2, 2003

Area 53 Motor Pool Marine Corps Base, Camp Pendleton, CA 92055 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109334029 OPENED DEC 10, 2002Closed

Planned · Complete · Safety · 3 employees at the site · Closed Feb 24, 2003

Area 31, 31614, Edson Range, Camp Pendleton, CA 92055 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$900$900Feb 14, 2003Closed
Citation 2, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Other-than-serious$0$0Feb 14, 2003Closed

Inspection 305567265 OPENED NOV 14, 2002Closed

Planned · Complete · Safety · 2 employees at the site · Closed Nov 14, 2002

Area 53 Motor Pool Marine Corps Base, Camp Pendleton, CA 92055 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305208241 OPENED JUL 3, 2002Closed

Planned · Complete · Safety · 6 employees at the site · Closed Sep 3, 2002

32nd St. Bldg 223, Naval Station, San Diego, CA 92136 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$525$525Aug 23, 2002Closed

Inspection 305208175 OPENED JUN 25, 2002Closed

Planned · Complete · Safety · 8 employees at the site · Closed Aug 7, 2002

Area 53 Motor Pool Marine Corps Base, Camp Pendleton, CA 92055 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$0$0Jul 30, 2002Closed
3 older inspections

Inspection 109336909 OPENED DEC 16, 1997Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 18, 1999

Bldg 24100 Brig, Mcb Camp Pendleton, CA 92055 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$750$750Feb 10, 1998Closed
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$750$750Feb 10, 1998Closed

Inspection 120017009 OPENED AUG 10, 1993Closed

Unprogrammed other · Partial · Safety · 11 employees at the site · Closed Oct 12, 1994

795 Folsom St.,#3, San Francisco, CA 94103 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1509 C
Other-than-serious$75$75Sep 28, 1993Closed

Inspection 112009543 OPENED APR 12, 1991Closed

Unprogrammed related · Partial · Safety · 6 employees at the site · Closed Apr 25, 1991

7689 & 7693 Pamilla Dr., San Diego, CA 92122 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1626 E
Other-than-serious$0$0Apr 24, 1991Closed
Citation 1, item 2
29 CFR 1626 B
Other-than-serious$0$0Apr 24, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other commercial and institutional building construction employers in California

Alert subscribers get notified of each newly cited employer in California the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.