OSHA SearchOSHA records by employer

A & D Roofing Co., Inc.: OSHA inspections and violations

New Rochelle, New York · Roofing Contractors · NAICS 238160

6inspections
14citation items
$12,850current penalties
Dec 19, 2023last inspection

A & D Roofing Co., Inc. has 6 OSHA inspections on record in New York, the first in 1996.

OSHA's last visit started on Dec 19, 2023 as a planned inspection, in Pelham.

Across those inspections OSHA issued 14 citation items: 13 serious and 1 other-than-serious.

OSHA proposed $20,016 in penalties. After settlements and reviews the total is $12,850, down 36%.

Most often, OSHA cited 1926.1053, ladders in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. A & D Roofing Co., Inc. averages $6,750 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

A & D Roofing Co., Inc.: OSHA citation items per year, 1996 to 2023
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

57 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch A & D Roofing Co., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347173619 OPENED DEC 19, 2023Closed

Planned · Complete · Safety · 10 employees at the site · Closed Feb 5, 2024

446 Esplanade, Pelham, NY 10803 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,679$1,687Dec 26, 2023Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,688$2,953Dec 26, 2023Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,349$2,110Dec 26, 2023Final

Inspection 343642500 OPENED DEC 6, 2018Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Apr 19, 2019

23 Bronxville Lane, Yonkers, NY 10701 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302806385 OPENED SEP 26, 2000Closed

Follow-up · Partial · Safety · 3 employees at the site · Closed Oct 5, 2000

60 Argyll Ave., New Rochelle, NY 10801 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302803713 OPENED FEB 17, 2000Closed

Accident · Complete · Safety · 4 employees at the site · Closed Sep 4, 2001

60 Argyll Ave., New Rochelle, NY 10801 · OSHA's record · Phone and website on Google Maps

Incident on Feb 15, 2000 (fatal): Employee killed in fall from roof

Employee #1 was removing old shingles and installing new ones on a single family residential home. He fell approximately 26 feet from the rake edge of the roof. He sustained head and internal injuries, resulting in his death.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$1,500Aug 2, 2000Closed
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Aug 2, 2000Closed
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,000$700Aug 2, 2000Closed
Citation 1, item 2b
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0Aug 2, 2000Closed
Citation 1, item 3
29 CFR 1926.1053(b)(7) · Ladders in construction
Serious$1,000$600Aug 2, 2000Closed
Citation 1, item 4
29 CFR 1926.1053(b)(9) · Ladders in construction
Serious$600$200Aug 2, 2000Closed
Citation 2, item 1
29 CFR 1904.8(a) · Recording criteria for needlestick and sharps injuries
Other-than-serious$2,000$1,000Aug 2, 2000Closed

Inspection 301458972 OPENED JUN 9, 1998Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Dec 17, 1998

52 Webster Ave., New Rochelle, NY 10801 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$600$600Aug 5, 1998Closed
Citation 1, item 2
29 CFR 1926.1052(a)(7) · Stairways in construction
Serious$600$600Aug 5, 1998Closed

Inspection 110606233 OPENED AUG 6, 1996Closed

Referral · Complete · Safety · 4 employees at the site · Closed Sep 30, 1996

18 Osborne Street, White Plains, NY 10601 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$900Aug 7, 1996Closed
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Aug 7, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.8 · Recording criteria for needlestick and sharps injuries

29 CFR 1904.8(a)

(a) Basic requirement. You must record all work-related needlestick injuries and cuts from sharp objects that are contaminated with another person's blood or other potentially infectious material (as defined by 29 CFR 1910.1030). You must enter the case on the OSHA 300 Log as an injury. To protect the employee's privacy, you may not enter the employee's name on the OSHA 300 Log (see the requirements for privacy cases in paragraphs 1904.29(b)(6) through 1904.29(b)(9)).

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.