OSHA SearchOSHA records by employer

A and G Stucco LLC: OSHA inspections and violations

Walker, Louisiana · Drywall and Insulation Contractors · NAICS 238310

1inspections
2citation items
$6,500current penalties
Mar 29, 2023last inspection

A and G Stucco LLC has one OSHA inspection on record in Louisiana.

OSHA opened it on Mar 29, 2023 as a planned inspection, in Walker.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $8,037 in penalties. After settlements and reviews the total is $6,500, down 19%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. A and G Stucco LLC averages $6,500 over 1 cited inspection in that time.

A and G Stucco LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch A and G Stucco LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346597313 OPENED MAR 29, 2023Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jul 1, 2025

10127 Us Hwy 190, Walker, LA 70785 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,572$3,250Apr 21, 2023Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,465$3,250Apr 21, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

Other drywall and insulation contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.