OSHA SearchOSHA records by employer

A & L Excavating and Sewer, Inc.: OSHA inspections and violations

Schiller Park, Illinois · Water and Sewer Line and Related Structures Construction · NAICS 237110

2inspections
9citation items
$11,700current penalties
Sep 7, 2023last inspection

A & L Excavating and Sewer, Inc. has 2 OSHA inspections on record in Illinois, the first in 2017.

OSHA's last visit started on Sep 7, 2023 as a planned inspection, in Northbrook.

Across those inspections OSHA issued 9 citation items: 9 serious.

OSHA proposed $21,253 in penalties. After settlements and reviews the total is $11,700, down 45%.

Most often, OSHA cited 1926.652, trench protection (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. A & L Excavating and Sewer, Inc. averages $5,850 over 2 cited inspections in that time.

A & L Excavating and Sewer, Inc.: OSHA citation items per year, 2017 to 2023
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

416employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch A & L Excavating and Sewer, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346960487 OPENED SEP 7, 2023Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 22, 2024

899 Skokie Blvd., Northbrook, IL 60062 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$2,679$1,400Sep 13, 2023Final
Citation 1, item 2
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$3,349$1,800Sep 13, 2023Final
Citation 1, item 3
29 CFR 1926.651(c)(2) · Excavations
Serious$4,018$2,300Sep 13, 2023Final
Citation 1, item 4a
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,688$2,500Sep 13, 2023Final
Citation 1, item 4b
29 CFR 1926.652(c)(2)(i) · Trench protection
Serious$0$0Sep 13, 2023Final
Citation 1, item 4c
29 CFR 1926.652(g)(2) · Trench protection
Serious$0$0Sep 13, 2023Final

Inspection 342352739 OPENED MAY 25, 2017Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 23, 2017

Des Plaines River Road And Irving Park Road, Schiller Park, IL 60131 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(i)(3) · Excavations
Serious$2,173$1,233May 31, 2017Final
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Serious$2,173$1,233May 31, 2017Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,173$1,234May 31, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.