OSHA SearchOSHA records by employer

A & M Roofing and Sheetmetal Co. Inc.: OSHA inspections and violations

Malden, Massachusetts · Roofing Contractors · NAICS 238160

5inspections
7citation items
$5,955current penalties
Jun 13, 2018last inspection

Since 1994, OSHA inspectors have visited A & M Roofing and Sheetmetal Co. Inc. in Massachusetts 5 times.

The most recent inspection opened on Jun 13, 2018 as a planned inspection, in Malden and is still open.

In all, OSHA issued 7 citation items: 2 serious, 1 repeat and 4 other-than-serious.

The proposed penalties came to $14,717; today they stand at $5,955, 60% less.

The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. A & M Roofing and Sheetmetal Co. Inc. averages $1,000 across 1 cited inspection.

A & M Roofing and Sheetmetal Co. Inc.: OSHA citation items per year, 1994 to 2018
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

266employers cited

56 of them in the same industry

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch A & M Roofing and Sheetmetal Co. Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343303244 OPENED JUN 13, 2018Open

Planned · Partial · Safety · 60 employees at the site · Open

700 Broadway St, Malden, MA 02148 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 343437869 OPENED JUN 13, 2018Closed

Planned · Partial · Safety · 60 employees at the site · Closed Mar 29, 2019

700 Broadway, Malden, MA 02148 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.454(c) · Scaffold training
Other-than-serious$6,467$1,000Sep 5, 2018Final

Inspection 334785441 OPENED JUN 16, 2012Closed

Unprogrammed other · Complete · Safety · 50 employees at the site · Closed Mar 21, 2013

203 Littleton Road, Westford, MA 01886 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Other-than-serious$3,150$2,205Sep 14, 2012Final

Inspection 315486613 OPENED APR 29, 2011Closed

Complaint · Complete · Safety · 50 employees at the site · Closed May 2, 2011

200 Leisure Lane, Stoneham, MA 02180 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 109162933 OPENED DEC 19, 1994Closed

Complaint · Complete · Safety · 3 employees at the site · Closed Jan 9, 1995

Bridgewater State College Science Building, Bridgewater, MA 02324 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(iii) · Ground-fault protection on job sites
Serious$900$475Dec 23, 1994Closed
Citation 1, item 2
29 CFR 1926.1051(a)(3) · Stairways and Ladders: general requirements
Serious$1,200$675Dec 23, 1994Closed
Citation 2, item 1
29 CFR 1926.500(g)(1) · Scope, application, and definitions applicable to this subpart
Repeat$3,000$1,600Dec 23, 1994Closed
Citation 3, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Other-than-serious$0$0Dec 23, 1994Closed
Citation 3, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Dec 23, 1994Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)(3)

(3) When a building or structure has only one point of access between levels, that point of access shall be kept clear to permit free passage of employees. When work must be performed or equipment must be used such that free passage at that point of access is restricted, a second point of access shall be provided and used.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(iii)

(iii) Assured equipment grounding conductor program. The employer shall establish and implement an assured equipment grounding conductor program on construction sites covering all cord sets, receptacles which are not a part of the building or structure, and equipment connected by cord and plug which are available for use or used by employees. This program shall comply with the following minimum requirements:

29 CFR 1926.454 · Scaffold training

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.