OSHA SearchOSHA records by employer

A & R Iron Works: OSHA inspections and violations

Brooklyn, New York · All Other Specialty Trade Contractors · NAICS 238990

2inspections
3citation items
$5,205current penalties
Jun 24, 2022last inspection

A & R Iron Works has 2 OSHA inspections on record in New York, the first in 2019.

OSHA's last visit started on Jun 24, 2022 to follow up on an earlier case, in Brooklyn.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $5,205 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.1052, stairways in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. A & R Iron Works averages $5,205 over 1 cited inspection in that time.

A & R Iron Works: OSHA citation items per year, 2019 to 2022
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

372employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch A & R Iron Works and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346042773 OPENED JUN 24, 2022Closed

Follow-up · Partial · Safety · 1 employee at the site · Closed Dec 16, 2022

239 Dahill Rd., Brooklyn, NY 11218 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344361449 OPENED OCT 7, 2019Closed

Planned · Partial · Safety · 2 employees at the site · Closed May 7, 2025

239 Dahill Rd., Brooklyn, NY 11218 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$2,313$2,313Mar 18, 2020Final
Citation 1, item 2a
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$2,892$2,892Mar 18, 2020Final
Citation 1, item 2b
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$0$0Mar 18, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.1052(c)(12)

(12) Unprotected sides and edges of stairway landings shall be provided with guardrail systems. Guardrail system criteria are contained in subpart M of this part.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

Other all other specialty trade contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.