Inspection 348053067 OPENED FEB 20, 2025Closed
3246 Collins Street, Philadelphia, PA 19134 · Machine Tool Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Philadelphia, Pennsylvania · Machine Tool Manufacturing · NAICS 333517
Since 1995, OSHA inspectors have visited A & S Manufacturing Inc in Pennsylvania 3 times.
The most recent inspection opened on Feb 20, 2025 after a complaint, in Philadelphia.
In all, OSHA issued 15 citation items: 14 serious and 1 other-than-serious.
The proposed penalties came to $25,665; today they stand at $21,415, 17% less.
The rule cited most here is 1910.219 (belts, pulleys and power-transmission parts), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. A & S Manufacturing Inc averages $18,915 across 1 cited inspection.
Pennsylvania · latest 90 days of OSHA records
280employers cited
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch A & S Manufacturing Inc and get notified the morning OSHA posts a new citation for it.
Watch this company3246 Collins Street, Philadelphia, PA 19134 · Machine Tool Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3246 Collins Street, Philadelphia, PA 19134 · Machine Tool Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(a)(3) · Walking-working surfaces |
Serious | $5,675 | $5,675 | Aug 15, 2025 | Final |
| Citation 1, item 2 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $6,620 | $6,620 | Aug 15, 2025 | Final |
| Citation 1, item 3 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $6,620 | $6,620 | Aug 15, 2025 | Final |
3246 Collins Street, Philadelphia, PA 19134 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.217(c)(1)(i) · Mechanical power presses |
Serious | $1,500 | $500 | Mar 16, 1995 | Closed |
| Citation 1, item 2 29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts |
Serious | $750 | $300 | Mar 16, 1995 | Closed |
| Citation 1, item 3a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $750 | $300 | Mar 16, 1995 | Closed |
| Citation 1, item 3b 29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Mar 16, 1995 | Closed |
| Citation 1, item 3c 29 CFR 1910.219(f)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Mar 16, 1995 | Closed |
| Citation 1, item 4 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $750 | $300 | Mar 16, 1995 | Closed |
| Citation 1, item 5 29 CFR 1910.305(a)(1)(i) · Electrical wiring methods |
Serious | $750 | $300 | Mar 16, 1995 | Closed |
| Citation 1, item 6 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $750 | $300 | Mar 16, 1995 | Closed |
| Citation 1, item 7 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $750 | $300 | Mar 16, 1995 | Closed |
| Citation 1, item 8a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $450 | $100 | Mar 16, 1995 | Closed |
| Citation 1, item 8b 29 CFR 1910.1200(h) · Hazard communication |
Serious | $0 | $0 | Mar 16, 1995 | Closed |
| Citation 2, item 1 29 CFR 1910.217(g) · Mechanical power presses |
Other-than-serious | $300 | $100 | Mar 16, 1995 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(h)
(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.
29 CFR 1910.212(a)(3)(ii)
(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.