OSHA SearchOSHA records by employer

A.E. New JR., Inc.: OSHA inspections and violations

Pensacola, Florida · Commercial and Institutional Building Construction · NAICS 236220

7inspections
16citation items
$70,990current penalties
Jan 26, 2015last inspection

OSHA has inspected A.E. New JR., Inc. 7 times in Florida since 1999.

The latest one began on Jan 26, 2015 as a planned inspection, in Milton.

Those inspections ended with 16 citation items: 12 serious, 3 willful and 1 repeat.

Penalties were first proposed at $72,475 and now stand at $70,990, 2% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and A.E. New JR., Inc. averages $2,940 (1 cited inspection).

A.E. New JR., Inc.: OSHA citation items per year, 1999 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch A.E. New JR., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340206887 OPENED JAN 26, 2015Closed

Planned · Complete · Safety · 15 employees at the site · Closed Apr 10, 2015

5317 Glover Lane, Milton, FL 32570 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$4,900$2,940Mar 17, 2015Final

Inspection 313878969 OPENED OCT 5, 2010Closed

Planned · Partial · Safety · 18 employees at the site · Closed Oct 14, 2010

100 North "p" Street, Pensacola, FL 32501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310032495 OPENED JUL 16, 2007Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Dec 3, 2007

500 West Maxwell Street, Pensacola, FL 32501 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$4,200$2,700Oct 24, 2007Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,575$1,050Oct 24, 2007Closed
Citation 1, item 3
29 CFR 1926.1052(b)(1) · Stairways in construction
Serious$675$425Oct 24, 2007Closed
Citation 1, item 4
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$675$425Oct 24, 2007Closed

Inspection 310030192 OPENED FEB 14, 2007Closed

Planned · Complete · Safety · 15 employees at the site · Closed May 22, 2008

3740 Excalibur Way, Milton, FL 32583 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$1,200$1,000Aug 13, 2007Final
Citation 1, item 2
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$2,800$2,000Aug 13, 2007Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,000$1,500Aug 13, 2007Final
Citation 1, item 4
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,000$3,000Aug 13, 2007Final
Citation 2, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Willful$44,000$24,000Aug 13, 2007Final
Citation 2, item 4a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Willful$0$27,000Aug 13, 2007Final
Citation 2, item 4b
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Willful$0$0Aug 13, 2007Final
Citation 3, item 1
29 CFR 1926.100(a) · Hard hats in construction
Repeat$4,000$2,500Aug 13, 2007Final

Inspection 306751926 OPENED JUL 15, 2004Closed

Complaint · Complete · Safety · 4 employees at the site · Closed Jan 5, 2005

313 Fairpoint Dr, Gulf Breeze, FL 32561 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$700$700Sep 10, 2004Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$875$875Sep 10, 2004Closed
Citation 1, item 3
29 CFR 1926.760(a)(1) · Fall protection
Serious$875$875Sep 10, 2004Closed

Inspection 303986772 OPENED OCT 16, 2001Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 16, 2001

1000 College Road, Blvd. 151, Pensacola, FL 32564 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302733902 OPENED OCT 19, 1999Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 19, 1999

208 Partin Drive, Niceville, FL 32578 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(1)

(1) Except during stairway construction, foot traffic is prohibited on stairways with pan stairs where the treads and/or landings are to be filled in with concrete or other material at a later date, unless the stairs are temporarily fitted with wood or other solid material at least to the top edge of each pan. Such temporary treads and landings shall be replaced when worn below the level of the top edge of the pan.

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.25 · Housekeeping

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.760 · Fall protection

Other commercial and institutional building construction employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.