OSHA SearchOSHA records by employer

A. Eagles Inc.: OSHA inspections and violations

New York, New York · Poured Concrete Foundation and Structure Contractors · NAICS 238110

2inspections
5citation items
$11,124current penalties
Mar 23, 2018last inspection

A. Eagles Inc. has 2 OSHA inspections on record in New York, the first in 2017.

OSHA's last visit started on Mar 23, 2018 to follow up on an earlier case, in New York.

Across those inspections OSHA issued 5 citation items: 5 serious.

OSHA proposed $11,124 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.134, respiratory protection (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. A. Eagles Inc. averages $5,562 over 2 cited inspections in that time.

A. Eagles Inc.: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites A. Eagles Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343038790 OPENED MAR 23, 2018Closed

Follow-up · Partial · Safety · 10 employees at the site · Closed Jan 11, 2023

627 Greenwich Street, New York, NY 10014 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$3,880$3,880Jun 28, 2018Final
Citation 1, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jun 28, 2018Final
Citation 1, item 1c
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Jun 28, 2018Final

Inspection 342218260 OPENED APR 3, 2017Closed

Programmed related · Partial · Safety · 8 employees at the site · Closed May 1, 2018

627 Greenwich St, New York, NY 10014 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$3,622$3,622Sep 8, 2017Final
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$3,622$3,622Sep 8, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(ii)

(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(k)(1)

(1) The employer shall ensure that each employee can demonstrate knowledge of at least the following:

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.404 · Ground-fault protection on job sites

Other poured concrete foundation and structure contractors employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.