OSHA SearchOSHA records by employer

A.H. Cornell & Son Inc.: OSHA inspections and violations

Horsham, Pennsylvania · Site Preparation Contractors · NAICS 238910

4inspections
6citation items
$13,863current penalties
Aug 14, 2020last inspection

OSHA has inspected A.H. Cornell & Son Inc. 4 times in Pennsylvania since 2000.

The latest one began on Aug 14, 2020 as a planned inspection, in Jamison.

Those inspections ended with 6 citation items: 6 serious.

Penalties were first proposed at $20,733 and now stand at $13,863, 33% lower after settlements or reviews.

Trench protection comes up most often in these citations: 3 items under 1926.652.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and A.H. Cornell & Son Inc. averages $6,136 (2 cited inspections).

A.H. Cornell & Son Inc.: OSHA citation items per year, 2000 to 2020
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

280employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch A.H. Cornell & Son Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344883756 OPENED AUG 14, 2020Closed

Planned · Partial · Safety · 30 employees at the site · Closed Nov 19, 2020

123 Main St., Jamison, PA 18929 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(k)(1) · Excavations
Serious$9,446$5,000Oct 9, 2020Final
Citation 1, item 1b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Oct 9, 2020Final

Inspection 342116134 OPENED FEB 15, 2017Closed

Referral · Partial · Safety · 6 employees at the site · Closed Mar 15, 2017

111 North Bethlehem Pike, Spring House, PA 19477 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$4,310$3,232Feb 22, 2017Final
Citation 1, item 2a
29 CFR 1926.651(j)(2) · Excavations
Serious$5,387$4,040Feb 22, 2017Final
Citation 1, item 2b
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Feb 22, 2017Final

Inspection 338194210 OPENED JAN 10, 2013Closed

Programmed other · Partial · Safety · 6 employees at the site · Closed Apr 22, 2013

700 Block Of E. Butler Ave., Doylestown, PA 18901 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(g)(2) · Trench protection
Serious$1,590$1,590Mar 18, 2013Final

Inspection 302334362 OPENED JAN 22, 2000Closed

Planned · No inspection · Safety · Closed Feb 25, 2000

Limekiln Pike & Fort Washington Ave., Horsham, PA 19044 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other site preparation contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.