OSHA SearchOSHA records by employer

A J Plumbing, Inc.: OSHA inspections and violations

Lutz, Florida · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
5citation items
$3,470current penalties
Aug 21, 2019last inspection

A J Plumbing, Inc. has one OSHA inspection on record in Florida.

OSHA opened it on Aug 21, 2019, in Lutz.

From that inspection OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $5,784 in penalties. After settlements and reviews the total is $3,470, down 40%.

Most often, OSHA cited 1926.1053, ladders in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. A J Plumbing, Inc. averages $3,470 over 1 cited inspection in that time.

A J Plumbing, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch A J Plumbing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344247465 OPENED AUG 21, 2019Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Feb 13, 2020

25900 Sierra Center Blvd, Lutz, FL 33548 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,892$1,735Jan 21, 2020Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,892$1,735Jan 21, 2020Final
Citation 1, item 2b
29 CFR 1926.1053(b)(6) · Ladders in construction
Serious$0$0Jan 21, 2020Final
Citation 1, item 2c
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$0$0Jan 21, 2020Final
Citation 2, item 1
29 CFR 1926.1053(b)(15) · Ladders in construction
Other-than-serious$0$0Jan 21, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(15)

(15) Ladders shall be inspected by a competent person for visible defects on a periodic basis and after any occurrence that could affect their safe use.

29 CFR 1926.1053(b)(6)

(6) Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.

29 CFR 1926.453 · Aerial lifts

Other plumbing, heating, and air-conditioning contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.