A L Tyler & Sons, Inc.: OSHA inspections and violations
Brattleboro, Vermont · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
16inspections
6citation items
$4,213current penalties
Aug 30, 2018last inspection
OSHA has inspected A L Tyler & Sons, Inc. 16 times in Vermont since 1973.
The latest one began on Aug 30, 2018, in West Dover.
Those inspections ended with 6 citation items: 5 serious and 1 other-than-serious.
Penalties were first proposed at $7,213 and now stand at $4,213, 42% lower after settlements or reviews.
Job-site wiring comes up most often in these citations: 5 items under 1926.405.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and A L Tyler & Sons, Inc. averages $1,663 (1 cited inspection).
A L Tyler & Sons, Inc. also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Vermont · latest 90 days of OSHA records
28employers cited
Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2022, the Brattleboro site logged 0 recordable injuries or illnesses among about 17 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
A.L. Tyler & Sons, Inc.
Brattleboro · 2022
17
0
0
0.0
1.8
Included with any plan: 1 more yearly log from these sites, back to 2020, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(C) Receptacles shall be of the grounding type. Unless installed in a complete metallic raceway, each branch circuit shall contain a separate equipment grounding conductor, and all receptacles shall be electrically connected to the grounding conductor. Receptacles for uses other than temporary lighting shall not be installed on branch circuits which supply temporary lighting. Receptacles shall not be connected to the same ungrounded conductor of multiwire circuits which supply temporary lighting.
29 CFR 1926.405(a)(2)(ii)(e)
(E) All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.
29 CFR 1926.405(a)(2)(iib)
(B) Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.
Other electrical contractors and other wiring installation contractors employers in Vermont
Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.