A Navarro Masonry Inc: OSHA inspections and violations

Charlotte, North Carolina · Masonry Contractors · NAICS 238140

1inspections
4citation items
$4,200current penalties
Sep 19, 2019last inspection

OSHA inspectors have visited A Navarro Masonry Inc in North Carolina one time.

It opened on Sep 19, 2019 as a planned inspection, in Charlotte.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $4,200 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. A Navarro Masonry Inc averages $4,200 across 1 cited inspection.

A Navarro Masonry Inc: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch A Navarro Masonry Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344325014 OPENED SEP 19, 2019Closed

Planned · Partial · Safety · 6 employees at the site · Closed Sep 3, 2025

Broadstone Bryant Park, 2140 Suttle Ave, Charlotte, NC 28208 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,100$2,100Dec 20, 2019Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Dec 20, 2019Final
Citation 1, item 2a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,100$2,100Dec 20, 2019Final
Citation 1, item 2b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Dec 20, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

Other masonry contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.