OSHA SearchOSHA records by employer

A1 Paris Construction Corp.: OSHA inspections and violations

Brooklyn, New York · Roofing Contractors · NAICS 238160

2inspections
3citation items
$12,288current penalties
Mar 29, 2022last inspection

A1 Paris Construction Corp. has 2 OSHA inspections on record in New York, the first in 2021.

OSHA's last visit started on Mar 29, 2022 to follow up on an earlier case, in Brooklyn.

Across those inspections OSHA issued 3 citation items: 3 serious.

OSHA proposed $12,288 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. A1 Paris Construction Corp. averages $12,288 over 1 cited inspection in that time.

A1 Paris Construction Corp.: OSHA citation items per year, 2021 to 2022
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

57 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch A1 Paris Construction Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345861660 OPENED MAR 29, 2022Closed

Follow-up · Partial · Safety · 1 employee at the site · Closed Apr 8, 2022

733 Westminster Rd., Brooklyn, NY 11230 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345456164 OPENED JUL 28, 2021Closed

Planned · Partial · Safety · 1 employee at the site · Closed Oct 7, 2024

733 Westminster Rd. 1 Fl., Brooklyn, NY 11230 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$4,096$4,096Dec 22, 2021Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,096$4,096Dec 22, 2021Final
Citation 1, item 3
29 CFR 1926.452(k)(1) · Rules for each type of scaffold
Serious$4,096$4,096Dec 22, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(k)(1)

(k) Ladder jack scaffolds. (1) Platforms shall not exceed a height of 20 feet (6.1 m).

Other roofing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.