OSHA SearchOSHA records by employer

Aaron King: OSHA inspections and violations

York, Pennsylvania · Roofing Contractors · NAICS 238160

2inspections
5citation items
$15,500current penalties
Jun 5, 2025last inspection

Since 2024, OSHA inspectors have visited Aaron King in Pennsylvania 2 times.

The most recent inspection opened on Jun 5, 2025 after a complaint, in Wyomissing.

In all, OSHA issued 5 citation items: 4 serious and 1 repeat.

The proposed penalties came to $24,250; today they stand at $15,500, 36% less.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Aaron King averages $7,750 across 2 cited inspections.

Aaron King: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Aaron King again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348290842 OPENED JUN 5, 2025Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Sep 29, 2026

1665 State Hill Rd Bon-ton, Berkshire Mall, Wyomissing, PA 19610 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,256$4,000Sep 12, 2025Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$4,256$4,000Sep 12, 2025Final
Citation 2, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$9,930$4,000Sep 12, 2025Final

Inspection 347810814 OPENED OCT 10, 2024Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 26, 2025

2603 Keyway Drive, York, PA 17402 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,457$1,750Nov 12, 2024Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,351$1,750Nov 12, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

Other roofing contractors employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.