OSHA SearchOSHA records by employer

Abbot O'Reilly Contracting, Inc.: OSHA inspections and violations

Montclair, New Jersey · Roofing Contractors · NAICS 238160

2inspections
8citation items
$11,729current penalties
Mar 8, 2017last inspection

Since 2013, OSHA inspectors have visited Abbot O'Reilly Contracting, Inc. in New Jersey 2 times.

The most recent inspection opened on Mar 8, 2017 after a complaint, in Newark.

In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

The proposed penalties came to $18,149; today they stand at $11,729, 35% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Abbot O'Reilly Contracting, Inc. averages $7,529 across 1 cited inspection.

Abbot O'Reilly Contracting, Inc.: OSHA citation items per year, 2013 to 2017
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

264employers cited

39 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Abbot O'Reilly Contracting, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342187713 OPENED MAR 8, 2017Closed

Complaint · Partial · Safety · 10 employees at the site · Closed Aug 8, 2019

572 Broad St, Newark, NJ 07102 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,183$2,510Jun 27, 2017Final
Citation 1, item 2
29 CFR 1926.451(e)(5)(i) · Scaffolds, general requirements
Serious$4,183$2,510Jun 27, 2017Final
Citation 1, item 3
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$4,183$2,510Jun 27, 2017Final

Inspection 338938988 OPENED MAR 4, 2013Closed

Referral · Complete · Health · 7 employees at the site · Closed Mar 5, 2014

596 Upper Mountain Ave., Montclair, NJ 07043 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,600$1,200Mar 26, 2013Final
Citation 1, item 2a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$1,500Mar 26, 2013Final
Citation 1, item 2b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Mar 26, 2013Final
Citation 1, item 3
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$2,000$1,500Mar 26, 2013Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Mar 26, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(2)(i)

(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.