OSHA SearchOSHA records by employer

Abc Construction: OSHA inspections and violations

Greenwich, Connecticut · Residential Remodelers · NAICS 236118

3inspections
9citation items
$5,275current penalties
Nov 25, 2015last inspection

Since 2005, OSHA inspectors have visited Abc Construction in Connecticut 3 times.

The most recent inspection opened on Nov 25, 2015 after a complaint, in Greenwich.

In all, OSHA issued 9 citation items: 8 serious and 1 other-than-serious.

The proposed penalties came to $7,750; today they stand at $5,275, 32% less.

The rule cited most here is 1926.1053 (ladders in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Abc Construction averages $2,800 across 1 cited inspection.

Abc Construction: OSHA citation items per year, 2005 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Abc Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341082410 OPENED NOV 25, 2015Closed

Complaint · Partial · Health · 5 employees at the site · Closed Jan 21, 2016

55 Fox Run Lane, Greenwich, CT 06830 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340533173 OPENED APR 10, 2015Closed

Planned · Partial · Safety · 24 employees at the site · Closed Dec 15, 2017

2 Sachatello Drive, Oakdale, CT 06370 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$2,800$2,800Jun 16, 2015Final

Inspection 309077824 OPENED NOV 15, 2005Closed

Referral · Partial · Safety · 12 employees at the site · Closed Jan 5, 2006

32 Vineyard Lane, Greenwich, CT 06831 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$1,050$525Dec 13, 2005Closed
Citation 1, item 2a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$450$225Dec 13, 2005Closed
Citation 1, item 2b
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0Dec 13, 2005Closed
Citation 1, item 3
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Serious$450$225Dec 13, 2005Closed
Citation 1, item 4
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$750Dec 13, 2005Closed
Citation 1, item 5a
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,500$750Dec 13, 2005Closed
Citation 1, item 5b
29 CFR 1926.1053(b)(7) · Ladders in construction
Serious$0$0Dec 13, 2005Closed
Citation 2, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0Dec 13, 2005Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.1053(b)(7)

(7) Ladders shall not be used on slippery surfaces unless secured or provided with slip-resistant feet to prevent accidental displacement. Slip-resistant feet shall not be used as a substitute for care in placing, lashing, or holding a ladder that is used upon slippery surfaces including, but not limited to, flat metal or concrete surfaces that are constructed so they cannot be prevented from becoming slippery.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

Other residential remodelers employers in Connecticut

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.