Inspection 344921424 OPENED SEP 10, 2020Closed
2303 Fm 1417, Sherman, TX 75092 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
Incident on Sep 4, 2020: Employee suffers shock after contacting energized circuit
At 4:00 p.m. on September 4, 2020, Employee #1 was working for a plumbing/HVAC contractor. Employee #1 was repairing a 460-volt A/C unit when his hand contacted a capacitor causing electric shocks and burns. Employee #1 was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Serious | $5,398 | $3,239 | Sep 18, 2020 | Final |
| Citation 1, item 2 29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection |
Serious | $8,096 | $4,858 | Sep 18, 2020 | Final |