The inspection began on Oct 13, 2022 as a planned inspection, in Austin.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $6,698 and still stand at $6,698.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Abigail Gonzalez averages $6,698 (1 cited inspection).

Abigail Gonzalez: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Abigail Gonzalez and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346282254 OPENED OCT 13, 2022Closed

Planned · Partial · Safety · 6 employees at the site · Closed Sep 22, 2025

830 East Anderson Lane, Austin, TX 78757 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$3,349$3,349Jan 26, 2023Final
Citation 1, item 2
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$3,349$3,349Jan 26, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(11)

(11) Steep roofs. Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.