OSHA SearchOSHA records by employer

Abingdon-Avon Cusd #276-High School: OSHA inspections and violations

Abingdon, Illinois · Elementary and Secondary Schools · NAICS 611110

2inspections
11citation items
$0current penalties
Sep 30, 2015last inspection

Abingdon-Avon Cusd #276-High School has 2 OSHA inspections on record in Illinois, the first in 2015.

OSHA's last visit started on Sep 30, 2015 as a planned inspection, in Abingdon.

Across those inspections OSHA issued 11 citation items: 9 serious and 2 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.1200, hazard communication (2 items).

For context, across all education employers the median penalty per cited inspection since 2015 is $0. Abingdon-Avon Cusd #276-High School averages $0 over 2 cited inspections in that time.

Abingdon-Avon Cusd #276-High School: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

428employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Abingdon-Avon Cusd #276-High School and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340906452 OPENED SEP 30, 2015Closed

Planned · Partial · Health · Local government · 45 employees at the site · Closed Jan 14, 2016

600 W Martin Street, Abingdon, IL 61410 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.252(c)(2)(ii) · Welding fire safety
Serious$0$0Nov 5, 2015Final
Citation 2, item 1
29 CFR 1910.1450(e)(1) · Occupational exposure to hazardous chemicals in laboratories
Other-than-serious$0$0Nov 5, 2015Final

Inspection 340881119 OPENED AUG 27, 2015Closed

Planned · Complete · Safety · Local government · 40 employees at the site · Closed Dec 11, 2015

600 W Martin Street, Abingdon, IL 61410 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.22(d)(1) · General requirements
Serious$0$0Nov 5, 2015Final
Citation 1, item 1b
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$0$0Nov 5, 2015Final
Citation 1, item 2
29 CFR 1910.106(g)(8) · Flammable liquids
Serious$0$0Nov 5, 2015Final
Citation 1, item 3
29 CFR 1910.106(g)(9) · Flammable liquids
Serious$0$0Nov 5, 2015Final
Citation 1, item 4
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$0$0Nov 5, 2015Final
Citation 1, item 5
29 CFR 1910.304(b)(3)(ii)(c)(3) · Grounding and circuit protection
Serious$0$0Nov 5, 2015Final
Citation 1, item 6
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Nov 5, 2015Final
Citation 1, item 7
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Nov 5, 2015Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Nov 5, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.106(g)(9)

(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.1450 · Occupational exposure to hazardous chemicals in laboratories

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.304 · Grounding and circuit protection

Other elementary and secondary schools employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.