Inspection 345839328 OPENED MAR 16, 2022Closed
540 North Freedom Street, Alliance, OH 44601 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2019, OSHA inspectors have visited Acme Surface Dynamics, Inc. in Ohio 2 times.
The most recent inspection opened on Mar 16, 2022 after a complaint, in Alliance.
In all, OSHA issued 17 citation items: 17 serious.
The proposed penalties came to $27,762; today they stand at $10,800, 61% less.
The rule cited most here is 1910.1026 (hexavalent chromium), 8 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Acme Surface Dynamics, Inc. averages $10,800 across 1 cited inspection.
Ohio · latest 90 days of OSHA records
273employers cited
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Ohio
Checking a subcontractor, a client or your own company? Watch Acme Surface Dynamics, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company540 North Freedom Street, Alliance, OH 44601 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
540 North Freedom Street, Alliance, OH 44601 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $5,398 | $2,600 | Mar 16, 2020 | Final |
| Citation 1, item 1b 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 1c 29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 1d 29 CFR 1910.134(k)(1) · Respiratory protection |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 2a 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Serious | $5,398 | $2,600 | Mar 16, 2020 | Final |
| Citation 1, item 2b 29 CFR 1910.146(d) · Permit-required confined spaces |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 2c 29 CFR 1910.146(g)(1) · Permit-required confined spaces |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 3 29 CFR 1910.146(c)(5)(ii)(b) · Permit-required confined spaces |
Serious | $3,856 | $1,200 | Mar 16, 2020 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $3,856 | $1,200 | Mar 16, 2020 | Final |
| Citation 1, item 5a 29 CFR 1910.1026(c) · Hexavalent chromium |
Serious | $5,398 | $3,200 | Mar 16, 2020 | Final |
| Citation 1, item 5b 29 CFR 1910.1026(d)(1) · Hexavalent chromium |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 5c 29 CFR 1910.1026(e)(1) · Hexavalent chromium |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 5d 29 CFR 1910.1026(f)(1)(i) · Hexavalent chromium |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 5e 29 CFR 1910.1026(k)(2)(i) · Hexavalent chromium |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 5f 29 CFR 1910.1026(h)(2)(iv) · Hexavalent chromium |
Serious | $3,856 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 5g 29 CFR 1910.1026(l)(2)(i) · Hexavalent chromium |
Serious | $0 | $0 | Mar 16, 2020 | Final |
| Citation 1, item 6b 29 CFR 1910.1026(i)(3)(ii) · Hexavalent chromium |
Serious | $0 | $0 | Mar 16, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1026(c)
(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of chromium (VI) in excess of 5 micrograms per cubic meter of air (5 µgm/m 3), calculated as an 8-hour time-weighted average (TWA).
29 CFR 1910.1026(d)(1)
(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.
29 CFR 1910.1026(e)(1)
(e) Regulated areas—(1) Establishment. The employer shall establish a regulated area wherever an employee's exposure to airborne concentrations of chromium (VI) is, or can reasonably be expected to be, in excess of the PEL.
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.