Acosta Masonry Inc.: OSHA inspections and violations

Leesburg, Virginia · Masonry Contractors · NAICS 238140

2inspections
10citation items
$3,039current penalties
Jan 13, 2016last inspection

Acosta Masonry Inc. has 2 OSHA inspections on record in Virginia, the first in 2006.

OSHA's last visit started on Jan 13, 2016, in Gloucester.

Across those inspections OSHA issued 10 citation items: 9 serious and 1 other-than-serious.

OSHA proposed $3,039 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Acosta Masonry Inc. averages $2,664 over 1 cited inspection in that time.

Acosta Masonry Inc.: OSHA citation items per year, 2006 to 2016
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

246employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Acosta Masonry Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341190635 OPENED JAN 13, 2016Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed May 18, 2016

Lot 58 Dunston Hall, Gloucester, VA 23061 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.50(c) · Medical services and first aid
Serious$576$576Mar 3, 2016Final
Citation 1, item 2
29 CFR 1926.50(d)(1) · Medical services and first aid
Serious$576$576Mar 3, 2016Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$756$756Mar 3, 2016Final
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$756$756Mar 3, 2016Final
Citation 2, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Mar 3, 2016Final

Inspection 309846921 OPENED FEB 15, 2006Closed

Planned · Complete · Safety · 8 employees at the site · Closed Apr 26, 2006

Lot 16 Crimson Place, Leesburg, VA 20175 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$375$375Apr 14, 2006Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Apr 14, 2006Closed
Citation 1, item 1c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Apr 14, 2006Closed
Citation 1, item 1d
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Apr 14, 2006Closed
Citation 1, item 1e
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0Apr 14, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.50 · Medical services and first aid

Other masonry contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.