OSHA SearchOSHA records by employer

Acoustical Drywall Systems Inc: OSHA inspections and violations

Kahului, Hawaii · Drywall and Insulation Contractors · NAICS 238310

6inspections
11citation items
$10,947current penalties
Jul 12, 2018last inspection

Acoustical Drywall Systems Inc has 6 OSHA inspections on record in Hawaii, the first in 2002.

OSHA's last visit started on Jul 12, 2018, in Lahaina.

Across those inspections OSHA issued 11 citation items: 7 serious, 1 repeat and 3 other-than-serious.

OSHA proposed $13,796 in penalties. After settlements and reviews the total is $10,947, down 21%.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Acoustical Drywall Systems Inc averages $4,347 over 1 cited inspection in that time.

Acoustical Drywall Systems Inc: OSHA citation items per year, 2002 to 2018
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

64employers cited

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch Acoustical Drywall Systems Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343304531 OPENED JUL 12, 2018Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed Sep 11, 2018

1221 Honoapiilani Hwy, Lahaina, HI 96761 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,174$1,630Aug 21, 2018Final
Citation 1, item 1b
29 CFR 1926.102(b)(1) · Eye and face protection in construction
Serious$0$0Aug 21, 2018Final
Citation 1, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$3,622$2,716Aug 21, 2018Final
Citation 2, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Aug 21, 2018Final

Inspection 340137819 OPENED DEC 4, 2014Closed

Unprogrammed other · Complete · Safety · 7 employees at the site · Closed Mar 10, 2015

101 Puunene Ave, Kahului, HI 96732 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$1,400$1,400Feb 24, 2015Final
Citation 1, item 2
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$1,000$1,000Feb 24, 2015Final

Inspection 316272061 OPENED SEP 11, 2013Closed

Unprogrammed other · Complete · Safety · 6 employees at the site · Closed Feb 5, 2014

511 Imi Pl, Wailuku, HI 96793 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Other-than-serious$0$0Dec 26, 2013Closed

Inspection 316270461 OPENED APR 19, 2013Closed

Referral · Partial · Safety · 14 employees at the site · Closed Mar 11, 2015

58 Maui Lani Way, Kahului, HI 96732 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$4,400$3,000Sep 20, 2013Closed

Inspection 313084444 OPENED JAN 12, 2012Closed

Referral · Partial · Safety · 9 employees at the site · Closed Mar 22, 2012

310 Ka'ahumanu Ave, Kahului, HI 96732 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$825$825Mar 8, 2012Closed

Inspection 305299521 OPENED JUN 18, 2002Closed

Referral · Partial · Safety · 2 employees at the site · Closed Jul 24, 2002

980 Lahainaluna Rd, Lahaina, HI 96761 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$375$375Jul 12, 2002Closed
Citation 2, item 1
29 CFR 1926.454(a)(4) · Scaffold training
Other-than-serious$0$0Jul 12, 2002Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.102(b)(1)

(b) Criteria for protective eye and face protection. (1) Protective eye and face protection devices must comply with any of the following consensus standards:

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.150 · Fire protection

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other drywall and insulation contractors employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.