OSHA SearchOSHA records by employer

Action Machine, Inc.: OSHA inspections and violations

South Bend, Indiana · Machine Shops · NAICS 332710

3inspections
13citation items
$990current penalties
Dec 13, 2022last inspection

Since 1982, OSHA inspectors have visited Action Machine, Inc. in Indiana 3 times.

The most recent inspection opened on Dec 13, 2022 as a planned inspection, in South Bend.

In all, OSHA issued 13 citation items: 6 serious and 7 other-than-serious.

The proposed penalties came to $2,850; today they stand at $990, 65% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Action Machine, Inc. averages $390 across 1 cited inspection.

Action Machine, Inc.: OSHA citation items per year, 1982 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Action Machine, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346388655 OPENED DEC 13, 2022Closed

Planned · Partial · Safety · 17 employees at the site · Closed Oct 5, 2023

1847 Prairie Avenue, South Bend, IN 46613 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$600$390Apr 3, 2023Final
Citation 1, item 1b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Apr 3, 2023Final

Inspection 127393916 OPENED DEC 28, 1999Closed

Planned · Complete · Safety · 13 employees at the site · Closed Mar 17, 2000

1847 Prairie Avenue, South Bend, IN 46613 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$600$100Feb 11, 2000Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$600$100Feb 11, 2000Closed
Citation 1, item 3
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$600$300Feb 11, 2000Closed
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$450$100Feb 11, 2000Closed
Citation 2, item 1
29 CFR 1910.38(a)(1) · Emergency action plans
Other-than-serious$0$0Feb 11, 2000Closed
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Feb 11, 2000Closed
Citation 2, item 3 Other-than-serious$0$0Feb 11, 2000Closed
Citation 2, item 4
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Feb 11, 2000Closed
Citation 2, item 5
29 CFR 1910.303(e) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 11, 2000Closed
Citation 2, item 6
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Feb 11, 2000Closed
Citation 2, item 7
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Feb 11, 2000Closed

Inspection 215173618 OPENED DEC 2, 1982Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 22, 1984

1855 Prairie Ave, South Bend, IN 46613 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.38 · Emergency action plans

Other machine shops employers in Indiana

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.