OSHA SearchOSHA records by employer

Action Plumbing Company: OSHA inspections and violations

Union City, Georgia · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

4inspections
13citation items
$12,493current penalties
Dec 4, 2017last inspection

OSHA has inspected Action Plumbing Company 4 times in Georgia since 1989.

The latest one began on Dec 4, 2017 after a complaint, in Jackson.

Those inspections ended with 13 citation items: 10 serious and 3 other-than-serious.

Penalties were first proposed at $21,466 and now stand at $12,493, 42% lower after settlements or reviews.

Excavations comes up most often in these citations: 3 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Action Plumbing Company averages $8,873 (1 cited inspection).

Action Plumbing Company: OSHA citation items per year, 1989 to 2017
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Action Plumbing Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342807245 OPENED DEC 4, 2017Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Nov 26, 2018

100 Van Mar Blvd, Jackson, GA 30233 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$8,873$4,436Dec 26, 2017Final
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Serious$8,873$4,436Dec 26, 2017Final

Inspection 302374319 OPENED APR 21, 1999Closed

Referral · Partial · Safety · 30 employees at the site · Closed May 20, 1999

Hwy. 10, Monroe, GA 30655 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,500$2,500May 3, 1999Closed
Citation 1, item 1b
29 CFR 1926.651(c)(2) · Excavations
Serious$0$0May 3, 1999Closed
Citation 1, item 1c
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0May 3, 1999Closed
Citation 1, item 2
29 CFR 1926.21(b)(2) · Construction safety training
Serious$750$750May 3, 1999Closed

Inspection 300973369 OPENED JAN 30, 1998Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Feb 17, 1998

Super 8 Exit 55a, Macon, GA 31210 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 18343954 OPENED OCT 19, 1989Closed

Planned · Complete · Safety · 7 employees at the site · Closed Feb 16, 1990

6840 Shannon Parkway South, Union City, GA 30291 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$120$120Nov 15, 1989Contested
Citation 1, item 2a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$200$100Nov 15, 1989Contested
Citation 1, item 2b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Nov 15, 1989Contested
Citation 1, item 3
29 CFR 1926.500(d)(2) · Scope, application, and definitions applicable to this subpart
Serious$150$150Nov 15, 1989Contested
Citation 2, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Nov 15, 1989Contested
Citation 2, item 2
29 CFR 1926.59(g)(1) · Hazard communication
Other-than-serious$0$0Nov 15, 1989Contested
Citation 2, item 3
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0Nov 15, 1989Contested

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(1)

(b) Guarding. (1) When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.59 · Hazard communication

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other plumbing, heating, and air-conditioning contractors employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.