OSHA SearchOSHA records by employer

Adamantium Solutions Inc.: OSHA inspections and violations

Englewood, Colorado · Cut Stone and Stone Product Manufacturing · NAICS 327991

2inspections
9citation items
$16,832current penalties
Jan 15, 2025last inspection

Adamantium Solutions Inc. has 2 OSHA inspections on record in Colorado, the first in 2023.

OSHA's last visit started on Jan 15, 2025 to follow up on an earlier case, in Englewood.

Across those inspections OSHA issued 9 citation items: 4 serious, 3 repeat and 2 other-than-serious.

OSHA proposed $28,137 in penalties. After settlements and reviews the total is $16,832, down 40%.

Most often, OSHA cited 1910.1053, silica dust in general industry (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Adamantium Solutions Inc. averages $8,416 over 2 cited inspections in that time.

Adamantium Solutions Inc.: OSHA citation items per year, 2023 to 2025
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Adamantium Solutions Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347978207 OPENED JAN 15, 2025Closed

Follow-up · Complete · Health · 7 employees at the site · Closed Jun 17, 2025

1960 W Bates Ave, Englewood, CO 80110 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$0$0Apr 25, 2025Final

Inspection 347023608 OPENED OCT 10, 2023Closed

Follow-up · Partial · Health · 7 employees at the site · Closed Oct 1, 2024

1960 W Bates Ave, Englewood, CO 80110 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$3,042$1,825Apr 1, 2024Final
Citation 1, item 2
29 CFR 1910.134(h)(1)(i) · Respiratory protection
Serious$3,042$1,824Apr 1, 2024Final
Citation 1, item 3a
29 CFR 1910.1053(f)(2)(i) · Silica dust in general industry
Serious$5,323$3,194Apr 1, 2024Final
Citation 1, item 3b
29 CFR 1910.1053(e)(4) · Silica dust in general industry
Serious$0$0Apr 1, 2024Final
Citation 2, item 1a
29 CFR 1910.1053(c) · Silica dust in general industry
Repeat$10,646$6,339Apr 1, 2024Final
Citation 2, item 1b
29 CFR 1910.1053(f)(1) · Silica dust in general industry
Repeat$0$0Apr 1, 2024Final
Citation 2, item 2
29 CFR 1910.134(f)(1) · Respiratory protection
Repeat$6,084$3,650Apr 1, 2024Final
Citation 3, item 1
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Other-than-serious$0$0Apr 1, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1053 · Silica dust in general industry

29 CFR 1910.1053(c)

(c) Permissible exposure limit (PEL). The employer shall ensure that no employee is exposed to an airborne concentration of respirable crystalline silica in excess of 50 µg/m 3, calculated as an 8-hour TWA.

29 CFR 1910.1053(e)(4)

(4) Provision of respirators. The employer shall provide each employee and the employee's designated representative entering a regulated area with an appropriate respirator in accordance with paragraph (g) of this section and shall require each employee and the employee's designated representative to use the respirator while in a regulated area.

29 CFR 1910.1053(f)(1)

(f) Methods of compliance—(1) Engineering and work practice controls. The employer shall use engineering and work practice controls to reduce and maintain employee exposure to respirable crystalline silica to or below the PEL, unless the employer can demonstrate that such controls are not feasible. Wherever such feasible engineering and work practice controls are not sufficient to reduce employee exposure to or below the PEL, the employer shall nonetheless use them to reduce employee exposure to the lowest feasible level and shall supplement them with the use of respiratory protection that complies with the requirements of paragraph (g) of this section.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

Other cut stone and stone product manufacturing employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.