OSHA SearchOSHA records by employer

Adjacent Bakery: OSHA inspections and violations

Scarborough, Maine · Commercial Bakeries · NAICS 311812

1inspections
3citation items
$3,768current penalties
Apr 27, 2018last inspection

OSHA inspectors have visited Adjacent Bakery in Maine one time.

It opened on Apr 27, 2018 after a complaint, in Scarborough.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $9,424; today they stand at $3,768, 60% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,872 penalty. Adjacent Bakery averages $3,768 across 1 cited inspection.

Adjacent Bakery: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Adjacent Bakery again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343118170 OPENED APR 27, 2018Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Jan 22, 2019

5 Lincoln Ave, Scarborough, ME 04074 · Commercial Bakeries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,772$1,108May 24, 2018Final
Citation 1, item 2
29 CFR 1910.263(f)(3) · Bakery equipment
Serious$3,326$1,330May 24, 2018Final
Citation 1, item 3
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$3,326$1,330May 24, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.263 · Bakery equipment

29 CFR 1910.263(f)(3)

(3) Rear of divider. The back of the divider shall have a complete cover to enclose all of the moving parts, or each individual part shall be enclosed or guarded to remove the separate hazards. The rear cover shall be provided with a limit switch in order that the machine cannot operate when this cover is open. The guard on the back shall be hinged so that it cannot be completely removed and if a catch or brace is provided for holding the cover open, it shall be designed so that it will not release due to vibrations or minor bumping whereby the cover may drop on an employee.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(iv)

(iv) There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.