OSHA SearchOSHA records by employer

Adon Cabrera: OSHA inspections and violations

Hanover, Maryland · Masonry Contractors · NAICS 238140

1inspections
5citation items
$875current penalties
Mar 11, 2019last inspection

OSHA has inspected Adon Cabrera once in Maryland.

The inspection began on Mar 11, 2019 as a planned inspection, in Hanover; the case is still open.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $875 and still stand at $875.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Adon Cabrera averages $875 (1 cited inspection).

Adon Cabrera: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Adon Cabrera again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343841839 OPENED MAR 11, 2019Open

Planned · Complete · Safety · 3 employees at the site · Open

7202-7206 Islips Way, Hanover, MD 21076 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$875$875Apr 30, 2019Final
Citation 1, item 1b
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$0$0Apr 30, 2019Final
Citation 1, item 1c
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Apr 30, 2019Final
Citation 1, item 1d
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Apr 30, 2019Final
Citation 1, item 1e
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Apr 30, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(c)(2)(i)

(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.

Other masonry contractors employers in Maryland