OSHA SearchOSHA records by employer

Adonai General Contractors Inc: OSHA inspections and violations

Hampton, Virginia · Commercial and Institutional Building Construction · NAICS 236220

2inspections
3citation items
$3,175current penalties
Nov 12, 2024last inspection

OSHA has inspected Adonai General Contractors Inc 2 times in Virginia since 2021.

The latest one began on Nov 12, 2024 after a complaint, in Virginia Beach.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $3,175 and still stand at $3,175.

Ladders in construction comes up most often in these citations: 2 items under 1926.1053.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Adonai General Contractors Inc averages $3,175 (1 cited inspection).

Adonai General Contractors Inc: OSHA citation items per year, 2021 to 2024
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

20 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Adonai General Contractors Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347872491 OPENED NOV 12, 2024Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Mar 24, 2025

660 Phoenix Drive, Virginia Beach, VA 23452 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,175$3,175Feb 17, 2025Final
Citation 1, item 1b
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$0$0Feb 17, 2025Final
Citation 1, item 1c
29 CFR 1926.1053(b)(21) · Ladders in construction
Serious$0$0Feb 17, 2025Final

Inspection 345324982 OPENED MAY 21, 2021Closed

Complaint · Partial · Health · 3 employees at the site · Closed Aug 24, 2021

2330 West Mercury Blvd Suite A, Hampton, VA 23666 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(21)

(21) Each employee shall use at least one hand to grasp the ladder when progressing up and/or down the ladder.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other commercial and institutional building construction employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.