Inspection 345470629 OPENED AUG 12, 2021Closed
625 W. Girard Ave., Philadelphia, PA 19123 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Philadelphia, Pennsylvania · Masonry Contractors · NAICS 238140
OSHA has inspected Advanced Contractor Corp. 2 times in Pennsylvania since 2021.
The latest one began on Aug 12, 2021 on a referral, in Philadelphia.
Those inspections ended with 5 citation items: 5 serious.
Penalties were first proposed at $19,895 and still stand at $19,895.
Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Advanced Contractor Corp. averages $19,895 (1 cited inspection).
Pennsylvania · latest 90 days of OSHA records
300employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Advanced Contractor Corp. and get notified the morning OSHA posts a new citation for it.
Watch this company625 W. Girard Ave., Philadelphia, PA 19123 · Framing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
801 N 40th Street, Philadelphia, PA 19104 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(c)(1) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Jan 14, 2022 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Jan 14, 2022 | Final |
| Citation 1, item 3 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Jan 14, 2022 | Final |
| Citation 1, item 4 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $4,096 | $4,096 | Jan 14, 2022 | Final |
| Citation 1, item 5 29 CFR 1926.451(h)(2) · Scaffolds, general requirements |
Serious | $3,511 | $3,511 | Jan 14, 2022 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(c)(1)
(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(f)(7)
(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.