OSHA SearchOSHA records by employer

Advanced Digital Cable, Inc.: OSHA inspections and violations

Blairsville, Georgia · Fiber Optic Cable Manufacturing · NAICS 335921

2inspections
9citation items
$36,470current penalties
May 5, 2023last inspection

OSHA has inspected Advanced Digital Cable, Inc. 2 times in Georgia since 2019.

The latest one began on May 5, 2023 on a referral, in Blairsville.

Those inspections ended with 9 citation items: 8 serious and 1 other-than-serious.

Penalties were first proposed at $53,418 and now stand at $36,470, 32% lower after settlements or reviews.

Belts, pulleys and power-transmission parts comes up most often in these citations: 4 items under 1910.219.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Advanced Digital Cable, Inc. averages $18,235 (2 cited inspections).

It reported 1 severe injury to OSHA since 2015.

Advanced Digital Cable, Inc.: OSHA citation items per year, 2019 to 2023
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

142employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Advanced Digital Cable, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346759210 OPENED MAY 5, 2023Closed

Referral · Partial · Safety · 104 employees at the site · Closed Sep 13, 2023

326 Airport Industrial Drive, Blairsville, GA 30512 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$11,050$11,050Aug 15, 2023Final

Inspection 343796983 OPENED FEB 13, 2019Closed

Referral · Partial · Safety · 77 employees at the site · Closed May 2, 2019

326 Airport Industrial Drive, Blairsville, GA 30512 · Fiber Optic Cable Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 22, 2019: Employee amputates finger while wiring machine

At 1:15 p.m. on January 22, 2019, an employee was preparing wire for a welded cross over on machine when he dropped the wire onto a running spool. The employee reached in to grab the wire and caught his hand against the wall of a guide cone. The employee amputated a finger and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$7,246$4,347Mar 7, 2019Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$7,246$4,347Mar 7, 2019Final
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$11,934$7,160Mar 7, 2019Final
Citation 1, item 4a
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$7,246$4,347Mar 7, 2019Final
Citation 1, item 4b
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 7, 2019Final
Citation 1, item 5a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$7,246$4,347Mar 7, 2019Final
Citation 1, item 5b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 7, 2019Final
Citation 2, item 1
29 CFR 1904.29(b)(3) · Injury and illness log
Other-than-serious$1,450$870Mar 7, 2019Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 22, 2019, Blairsville: Amputation · amputations · fingertip(s)

An employee was feeding the cone on a machine with wire. The wire wrapped around the employee's hand, causing the amputation of a fingertip.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(3)

(3) How quickly must each injury or illness be recorded? You must enter each recordable injury or illness on the OSHA 300 Log and 301 Incident Report within seven (7) calendar days of receiving information that a recordable injury or illness has occurred.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

Other fiber optic cable manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.