OSHA SearchOSHA records by employer

Advanced Environmental Air Technology, Inc.: OSHA inspections and violations

Houston, Texas · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
1citation items
$3,880current penalties
Jun 6, 2018last inspection

Advanced Environmental Air Technology, Inc. has one OSHA inspection on record in Texas.

OSHA opened it on Jun 6, 2018 after a fatality or catastrophe, in Houston.

From that inspection OSHA issued 1 citation item: 1 serious.

OSHA proposed $3,880 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Advanced Environmental Air Technology, Inc. averages $3,880 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Advanced Environmental Air Technology, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Advanced Environmental Air Technology, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343209631 OPENED JUN 6, 2018Closed

Fatality or catastrophe · Partial · Safety · 1 employee at the site · Closed Jan 7, 2019

5810 Dierker Drive, Houston, TX 77041 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jun 4, 2018 (fatal): Employee falls through skylight and is killed

At 12:06 p.m. on June 4, 2018, an employee was checking on an air conditioning unit on the roof of a commercial building. The employee started spraying a wasp nest with wasp killer. He started to walk backwards away from the nest and fell through a skylight. The employee died from blunt force trauma to the head and body.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(3)(i) · Fall protection in general industry
Serious$3,880$3,880Sep 25, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.28(b)(3)(i)

(i) Each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following:

Other plumbing, heating, and air-conditioning contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.