Inspection 345646533 OPENED OCT 8, 2021Closed
4256 Tilly Mill Road, Doraville, GA 30360 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2015, OSHA inspectors have visited Advanced Exteriors, LLC in Georgia 3 times.
The most recent inspection opened on Oct 8, 2021, in Doraville.
In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.
The proposed penalties came to $11,968; today they stand at $6,120, 49% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Advanced Exteriors, LLC averages $3,060 across 2 cited inspections.
Georgia · latest 90 days of OSHA records
147employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Georgia
Checking a subcontractor, a client or your own company? Watch Advanced Exteriors, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company4256 Tilly Mill Road, Doraville, GA 30360 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2715 Old Milton Pkwy., Alpharetta, GA 30009 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $5,834 | $4,584 | Jun 3, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Other-than-serious | $3,334 | $0 | Jun 3, 2019 | Final |
2600 Milscott Drive Building 1000b, Decatur, GA 30033 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.452(c)(4) · Rules for each type of scaffold |
Serious | $2,800 | $1,536 | Jan 7, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.452(c)(4)
(4) Where uplift can occur which would displace scaffold end frames or panels, the frames or panels shall be locked together vertically by pins or equivalent means.
29 CFR 1926.501(b)(1)
(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.
29 CFR 1926.701(b)
(b) Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement.
Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.