OSHA SearchOSHA records by employer

Advanced Wall Systems, Inc.: OSHA inspections and violations

Glendale, New York · Painting and Wall Covering Contractors · NAICS 238320

6inspections
20citation items
$71,046current penalties
Jul 9, 2019last inspection

OSHA has inspected Advanced Wall Systems, Inc. 6 times in New York since 1990.

The latest one began on Jul 9, 2019 after a complaint, in Poughkeepsie.

Those inspections ended with 20 citation items: 16 serious, 1 willful and 3 other-than-serious.

Penalties were first proposed at $71,346 and now stand at $71,046, 0% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 10 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Advanced Wall Systems, Inc. averages $27,468 (2 cited inspections).

Advanced Wall Systems, Inc.: OSHA citation items per year, 1990 to 2019
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Advanced Wall Systems, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344173067 OPENED JUL 9, 2019Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Apr 3, 2023

Poughkeepsie Plaza 2600 South Rd., Poughkeepsie, NY 12601 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(2)(i) · Scaffolds, general requirements
Serious$3,978$3,978Oct 25, 2019Final
Citation 1, item 2
29 CFR 1926.451(f)(12) · Scaffolds, general requirements
Serious$3,978$3,978Oct 25, 2019Final
Citation 1, item 3
29 CFR 1926.452(c)(4) · Rules for each type of scaffold
Serious$2,842$2,842Oct 25, 2019Final
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$3,978$3,978Oct 25, 2019Final

Inspection 343918322 OPENED APR 9, 2019Closed

Referral · Complete · Safety · 6 employees at the site · Closed Mar 18, 2026

805 Mamaroneck Ave., Mamaroneck, NY 10543 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$2,273$2,273Sep 30, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,842$2,842Sep 30, 2019Final
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Serious$3,978$3,978Sep 30, 2019Final
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,705$1,705Sep 30, 2019Final
Citation 1, item 5
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,842$2,842Sep 30, 2019Final
Citation 2, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Willful$26,520$26,520Sep 30, 2019Final
Citation 3, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Sep 30, 2019Final
Citation 3, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Sep 30, 2019Final
Citation 3, item 3
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Sep 30, 2019Final

Inspection 314981507 OPENED DEC 20, 2011Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Jun 13, 2016

3026 East Main Street, Cortlandt Manor, NY 10567 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,200$4,200Jun 18, 2012Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,200$4,200Jun 18, 2012Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,200$4,200Jun 18, 2012Closed

Inspection 309209377 OPENED SEP 20, 2006Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed Apr 11, 2007

Canal Street, Port Ewen, NY 12466 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301458766 OPENED MAY 14, 1998Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jun 30, 1998

2 Dana Road, Valhalla, NY 10591 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$1,000$700Jun 12, 1998Closed

Inspection 102666377 OPENED NOV 8, 1990Closed

Complaint · Complete · Safety · 3 employees at the site · Closed Oct 5, 1993

8000 Cooper Avenue, Bldg. 15, Glendale, NY 11327 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$810$810Jan 24, 1991Closed
Citation 1, item 2
29 CFR 1926.451(d)(7) · Scaffolds, general requirements
Serious$1,000$1,000Jan 24, 1991Closed
Citation 1, item 3
29 CFR 1926.451(d)(10) · Scaffolds, general requirements
Serious$1,000$1,000Jan 24, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other painting and wall covering contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.