OSHA SearchOSHA records by employer

Aecom: OSHA inspections and violations

Fort Polk, Louisiana · Other General Government Support · NAICS 921190

1inspections
4citation items
$39,780current penalties
Jun 26, 2019last inspection

OSHA inspectors have visited Aecom in Louisiana one time.

It opened on Jun 26, 2019 on a referral, in Fort Polk.

In all, OSHA issued 4 citation items: 4 other-than-serious.

The penalties, $39,780 in total, stand where OSHA first set them.

The rule cited most here is 1910.252 (welding fire safety), 4 times.

Among public administration employers, the typical cited inspection since 2015 ends with a $0 penalty. Aecom averages $39,780 across 1 cited inspection.

It reported 2 severe injuries to OSHA since 2015.

Aecom: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Aecom again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344114939 OPENED JUN 26, 2019Closed

Referral · Partial · Safety · 600 employees at the site · Closed Aug 3, 2020

2350 Louisiana Avenue Bldg 4386, Fort Polk, LA 71459 · Other General Government Support · OSHA's record · Phone and website on Google Maps

Incident on Jun 24, 2019: Employee is burned when welding on tank that explodes

At 1:45 p.m. on June 24, 2019, Employee #1 was welding tabs on two fuel tanks. The tanks were newly fabricated, but the fuel pumps affixed to them, one gasoline and one diesel, were used and contained residual fumes. Employee #1 completed welding on the diesel fuel tank. He was standing in the bed of a truck welding tabs on the gasoline fuel tank when the tank exploded and caused Employee #1 to catch fire. Coworkers used a fire extinguisher and patted out the fire on Employee #1, and they helped Employee #1 pull off his two shirts. Employee #1 was hospitalized overnight with second degree burns to his face, chest, and arms from the fire.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.252(a)(2)(vi)(c) · Welding fire safety
Other-than-serious$13,260$26,520Jul 24, 2019Final
Citation 1, item 1b
29 CFR 1910.252(a)(2)(xiii)(d) · Welding fire safety
Other-than-serious$13,260$0Jul 24, 2019Final
Citation 1, item 2
29 CFR 1910.252(a)(3)(i) · Welding fire safety
Other-than-serious$13,260$13,260Jul 24, 2019Final
Citation 1, item 2b
29 CFR 1910.252(a)(3)(ii) · Welding fire safety
Other-than-serious$0$0Jul 24, 2019Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Jun 24, 2019, Fort Polk: Hospitalization · heat (thermal) burns, unspecified · head and trunk

An employee was welding on a newly fabricated fuel tank when a flash fire occurred. Residual fumes in the tank ignited and flames exited the tank opening, causing burns to the employee's face and chest.

Dec 6, 2017, Fort Polk: Hospitalization · fractures · leg(s), unspecified

An employee was getting off a skid steer when his foot slipped and became lodged between the mast and the equipment. He broke his right leg, requiring hospitalization.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.252(a)(2)(vi)(c)

(C) In the presence of explosive atmospheres (mixtures of flammable gases, vapors, liquids, or dusts with air), or explosive atmospheres that may develop inside uncleaned or improperly prepared tanks or equipment which have previously contained such materials, or that may develop in areas with an accumulation of combustible dusts.

29 CFR 1910.252(a)(2)(xiii)(d)

(D) Advise all contractors about flammable materials or hazardous conditions of which they may not be aware.

29 CFR 1910.252(a)(3)(i)

(3) Welding or cutting containers—(i) Used containers. No welding, cutting, or other hot work shall be performed on used drums, barrels, tanks or other containers until they have been cleaned so thoroughly as to make absolutely certain that there are no flammable materials present or any substances such as greases, tars, acids, or other materials which when subjected to heat, might produce flammable or toxic vapors. Any pipe lines or connections to the drum or vessel shall be disconnected or blanked.

Other other general government support employers in Louisiana

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.