OSHA SearchOSHA records by employer

Afa Industries Inc: OSHA inspections and violations

Romeo, Michigan · Gasket, Packing, and Sealing Device Manufacturing · NAICS 339991

2inspections
27citation items
$1,220current penalties
Apr 12, 2016last inspection

OSHA has inspected Afa Industries Inc 2 times in Michigan since 2014.

The latest one began on Apr 12, 2016 as a planned inspection, in Romeo.

Those inspections ended with 27 citation items: 12 serious, 3 repeat and 12 other-than-serious.

Penalties were first proposed at $2,600 and now stand at $1,220, 53% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 3 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Afa Industries Inc averages $300 (1 cited inspection).

Afa Industries Inc: OSHA citation items per year, 2014 to 2016
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

656employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Afa Industries Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340036219 OPENED APR 12, 2016Closed

Planned · Complete · Safety · 11 employees at the site · Closed Aug 10, 2016

140 E Pond Dr, Romeo, MI 48065 · Gasket, Packing, and Sealing Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.12154(1)
Repeat$100$100May 6, 2016Final
Citation 1, item 2
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Repeat$100$100May 6, 2016Final
Citation 1, item 3
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Repeat$100$100May 6, 2016Final

Inspection 315373365 OPENED FEB 3, 2014Closed

Planned · Complete · Safety · 13 employees at the site · Closed May 12, 2015

140 E Pond Dr, Romeo, MI 48065 · Gasket, Packing, and Sealing Device Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$350$140Apr 2, 2014Final
Citation 1, item 1b Serious$0$0Apr 2, 2014Final
Citation 1, item 2a Serious$200$80Apr 2, 2014Final
Citation 1, item 2b Serious$0$0Apr 2, 2014Final
Citation 1, item 2c Serious$0$0Apr 2, 2014Final
Citation 1, item 3 Serious$200$80Apr 2, 2014Final
Citation 1, item 4 Serious$200$80Apr 2, 2014Final
Citation 1, item 5 Serious$200$80Apr 2, 2014Final
Citation 1, item 6 Serious$250$100Apr 2, 2014Final
Citation 1, item 7 Serious$200$80Apr 2, 2014Final
Citation 1, item 8
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$350$140Apr 2, 2014Final
Citation 1, item 9
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$250$100Apr 2, 2014Final
Citation 2, item 1 Other-than-serious$100$40Apr 2, 2014Final
Citation 2, item 2 Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 3 Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 4 Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 5a Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 5b Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 6a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 6b
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 6c
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 6d
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 7 Other-than-serious$0$0Apr 2, 2014Final
Citation 2, item 8
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Apr 2, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(f)(2)(ii)

(ii) Containers when stored inside shall not be located near exits, stairways, or in areas normally used or intended for the safe exit of people.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 4081.1732

29 CFR 4081.213

29 CFR 4081.2131

29 CFR 4081.2154

29 CFR 4081.2164

29 CFR 4081.2176

29 CFR 4081.231

29 CFR 4081.3308

29 CFR 4081.3309

29 CFR 4081.4007

29 CFR 4081.433

29 CFR 4081.631

29 CFR 4081.632

29 CFR 4081.645

29 CFR 4081.727

29 CFR 4081.835

29 CFR 4082.2129

Other gasket, packing, and sealing device manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.