OSHA SearchOSHA records by employer

Affordable Home Restoration LLC: OSHA inspections and violations

New Haven, Connecticut · Roofing Contractors · NAICS 238160

4inspections
7citation items
$16,353current penalties
Nov 16, 2021last inspection

OSHA has inspected Affordable Home Restoration LLC 4 times in Connecticut since 2017.

The latest one began on Nov 16, 2021 as a planned inspection, in Manchester.

Those inspections ended with 7 citation items: 6 serious and 1 repeat.

Penalties were first proposed at $23,478 and now stand at $16,353, 30% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 2 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Affordable Home Restoration LLC averages $5,451 (3 cited inspections).

Affordable Home Restoration LLC: OSHA citation items per year, 2017 to 2021
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

84employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Affordable Home Restoration LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345640106 OPENED NOV 16, 2021Closed

Planned · Partial · Safety · 6 employees at the site · Closed Aug 28, 2023

243 Main Street, Manchester, CT 06040 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,218$2,253Jan 4, 2022Final

Inspection 344607197 OPENED FEB 5, 2020Closed

Follow-up · No inspection · Safety · 5 employees at the site · Closed Feb 5, 2020

511 Townsend Avenue, New Haven, CT 06512 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343859989 OPENED MAR 19, 2019Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Apr 6, 2023

511 Townsend Ave., New Haven, CT 06512 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,273$1,500May 1, 2019Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$8,752$6,200May 1, 2019Final

Inspection 342341781 OPENED MAY 19, 2017Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jan 3, 2018

9 Demorest St., Waterbury, CT 06710 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,716$1,800Jun 14, 2017Final
Citation 1, item 2a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,716$1,800Jun 14, 2017Final
Citation 1, item 2b
29 CFR 1926.454(a)(1) · Scaffold training
Serious$0$0Jun 14, 2017Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,803$2,800Jun 14, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.